Basic cleaning
Basic cleaning
Basic cleaning
Basic cleaning
•
Drain the old glue via the tank filter.
•
Loosen coarse debris from the tank by using a wooden spatula. If the contaminants are very
strong, please contact UES AG for information on alternative cleaning options. Fill new glue
into the tank and set the temperatures for the material hoses down to about 90 °C so that
the glue becomes more viscous.
•
Loosen the hoses from the heads and hang them in a collection container.
•
Set a high pump pressure so that the viscous glue is pumped through the system and
hardened glue can mostly be rinsed out.
•
If only clean adhesive flows out of the hoses, switch off the pump and attach the application
heads.
•
Screw off the nozzles and repeat step 6. (Follow the safety instructions)
•
Screw the nozzles back on.
•
After the nozzles are heated, your system is ready for use again.