Application head connection
Application head connection
Application head connection
Application head connection
The glue connection nipple on the application head has to be connected to the hose connection
nipple on the hose. You will also need an SW 19 wrench.
The electrical connection is established by inserting the plug located on the application head into the
socket located on the glue hose.
Warning!
Make sure that there is an absolutely tight connection between the system, the hoses and the
guns via the screwed glue nipple. Otherwise, any escaping glue can lead to severe burns.
Pneumatic components are designed and constructed according to the applicable standards and
calculations such that, under the intended conditions of use, rupture or failure due to fatigue or
wear is not expected to occur.
Add glue
Add glue
Add glue
Add glue
Caution:
When refilling the glue, any spouting hot glue can cause injuries.
In any case, observe the safety regulations for handling melted adhesives.
•
Do not leave the adhesive supply open; only store it in sealed containers.
•
The fuel tank lid should be able to be opened without foreign bodies (such as scraps of paper)
being able to fall into it.
•
Before filling, check to see whether the tank and the adhesive supply are clean and free of debris.
•
Do not overfill your system.
Add adhesive carefully to a max. 20 mm below the tank opening.
•
Close the tank lid after filling. This prevents unwanted foreign matter from entering the tank or
hot adhesive vapours from escaping.
•
The tank lid should be closed without it coming into direct contact with the adhesive.
•
Do not run your device when it is completely empty. If there is too little adhesive in the tank,
localised overheating can result in
•
glue burns and deposits in your system, leading to a malfunction.
•
Refer to the data sheet of your adhesive supplier and set your device appropriately.