88 | SWIFT K33A ALL IN ONE FUSION SPLICER
americanilsintech.com | 89
ERROR MESSAGES
TOO DIRTY FIBER
Displayed when the optical system determines the prepped fi ber is contaminated and will
inhibit the ability of the K33A to perform a quality splice. To remedy open the wind cover,
remove the dirty fi ber, clean, cleave and then replace it into the splice chamber.
Replace the optical fi ber. This message is displayed when the fi ber is not correctly situated
in the middle of the electrodes and V- groove or the optical lenses are dirty or obstructed.
To clear this message, press the remove the fi ber and place it in the fusion
chamber. If this error continues clean the optical lenses.
TOO LONG FIBER
The Too Long Fiber error message is displayed with the fi ber end is placed too close to
the electrodes or the cleave length is too long and the tip of the fi ber extends beyond the
default limit. A dirty lens or weak LED light can also cause this error, but most instances are
attributed to the fi ber length. Call your representative if this problem persists.
To Clear this error Press and place the fi ber in the fusion chamber. If error persist
remove dust and dirt from the lenses. Conduct an LED test. If an error occurs, contact
UCLSWIFT Co., Ltd.
FIBER OVER ANGLE
Fiber over Angle error is displayed when the measured cleaving angle of the fi ber is
greater than the limit. This error will be displayed and the faulty cleave angle value will be
displayed in Red. Green values displayed are within acceptable limits. The default cleave
angle is set for 2.0- higher values will appear and red and lower values will appear in green.
To clear this error, remove the fi ber with the high value and strip, clean and cleave it
again. Be sure that the cleaver is clean and free of debris prior to cleaving the fi ber. If this
condition persists, contact your sales representative.