70 | SWIFT K33A ALL IN ONE FUSION SPLICER
americanilsintech.com | 71
DEFAULT SETTINGS MENU
There are 4 specifi c Default options. See the chart below for and explanation of each
unique function. To activate a Default option, enable a check in the box next to the option
and to disable an option remove the check in the box next to the option. Select the check
mark to save your changes.
PARAMETERS
DESCRIPTION
Auto Splice
Performs the splice process automatically upon closing with wind
cover with no pause after the fi nal alignment.
Pause 1
Stops after initial fl ash clean process completes. Press and it
goes to the next step.
Pause 2
Stops after fi nal alignment completes. Press to perform the
fi nal splice.
Auto Heat
Powers on the sleeve heater automatically once the wind cover is
opened after splicing a successful splice.
MENU LOCK
Menu Lock enables the user settings for Splice, Heat, Memory and Password to be locked/
enabled to minimize the ability of these features to inadvertently be changed. To activate
the protection of these settings, place a check in the box next to the feature and to disable
remove the check next to the feature. You have to remember the password, if you forget or
lose the password the K33A will need to send it in for service to resolve this issue.
TEST ITEM
DESCRIPTION
Splice Lock
Locks the ability to change the splice mode settings
Heat Lock
Locks the ability to change the heat mode settings
Clear memory Lock
Lock the ability to change or delete the memory data
Password Query
Initiates a password menu, the default password is “1234”.
1
2
3
4