60 | SWIFT K33A ALL IN ONE FUSION SPLICER
americanilsintech.com | 61
PROGRAMMING A HEATER SETTING
From the main menu press on either the K33A or its touch screen. Next press the
“Heater” icon on the touch screen. This will display the pre-programmed heater menu
options. Use the arrows on the LCD display to scroll through the available settings and
Select the desired setting from LCD Screen and the setting Number and Name will be
displayed on the top of the LCD screen.
Select Cancel to return to the Swift K33A menu screen, then ready to return to the
Ready Screen.
DELETE A HEATER SETTING
Heater Settings 1-40 are system default settings and cannot be deleted.
User Settings 40-300 can be deleted. To Delete a user setting from the main menu press
on either the K33A or its touch screen. Next press the “Heater” icon on the touch screen. This will
display the pre-programmed heater menu options. Use the arrows on the LCD display to scroll
through the available settings and Select the desired setting to be deleted from LCD Screen
and the setting Number and Name will be displayed on the top of the LCD screen. Select the
DEL option and the setting will be deleted. Select cancel to return to the Heater Menu and be
sure to select an appropriate Heater Mode option as the K33A will default to Option 1.
REPLACE A HEATER SETTING
Users can only Replace a user created Heater mode setting. This function gives the ability
to replace a user defi ned setting with up to 40 stored splicing confi gurations of fi ber
stored in the K33A memory.
To replace a user defi ned setting select Menu from the LCD display or from the
K33A. Next select “Heater” menu using the touch screen. Using the arrows on the LCD
screen scroll to page that lists the setting that needs to replace and select it on the LCD
screen and the select “Replace”. The splice modes stored in memory are displayed on
the screen, select the desired Heater mode to be replaced and select “OK”. The selected
Heater mode replaces the last blank entry in the splicer menu.
NOTE:
Heater modes from 1 - 40 cannot be replaced.