LISA-U2 series - System integration manual
UBX-13001118 - R27
System description
Page 76 of 183
C1-Public
☞
The USB profile cannot be changed on the "01", "x2", "63" and "68" product versions of LISA-U2
series modules, as the AT+UUSBCONF command is not supported.
☞
The USB profile change, triggered by means of the AT+UUSBCONF command, is not performed at
run-time. The settings are saved in the Non-Volatile Memory at the module power-off, triggered
by means of the AT+CPWROFF command, and the new configuration will be effective at the
subsequent module reboot.
Default profile configuration
Interface 0
Abstract Control Model
EndPoint
Transfer: Interrupt
Interface 1
Data
EndPoint
Transfer: Bulk
EndPoint
Transfer: Bulk
Function AT and Data
Interface 2
Abstract Control Model
EndPoint
Transfer: Interrupt
Interface 3
Data
EndPoint
Transfer: Bulk
EndPoint
Transfer: Bulk
Function AT and Data
Interface 4
Abstract Control Model
EndPoint
Transfer: Interrupt
Interface 5
Data
EndPoint
Transfer: Bulk
EndPoint
Transfer: Bulk
Function AT and Data
Interface 6
Abstract Control Model
EndPoint
Transfer: Interrupt
Interface 7
Data
EndPoint
Transfer: Bulk
EndPoint
Transfer: Bulk
Function GNSS tunneling
Interface 8
Abstract Control Model
EndPoint
Transfer: Interrupt
Interface 9
Data
EndPoint
Transfer: Bulk
EndPoint
Transfer: Bulk
Function Primary Log
Interface 10
Abstract Control Model
EndPoint
Transfer: Interrupt
Interface 11
Data
EndPoint
Transfer: Bulk
EndPoint
Transfer: Bulk
Function Secondary Log
Interface 12
Abstract Control Model
EndPoint
Transfer: Interrupt
Interface 13
Data
EndPoint
Transfer: Bulk
EndPoint
Transfer: Bulk
Function SAP
Alternative profile configuration
Interface 0
Abstract Control Model
EndPoint
Transfer: Interrupt
Interface 1
Data
EndPoint
Transfer: Bulk
EndPoint
Transfer: Bulk
Function AT and Data
Interface 2
Abstract Control Model
EndPoint
Transfer: Interrupt
Interface 3
Data
EndPoint
Transfer: Bulk
EndPoint
Transfer: Bulk
Function GNSS tunneling
Interface 4
Abstract Control Model
EndPoint
Transfer: Interrupt
Interface 5
Data
EndPoint
Transfer: Bulk
EndPoint
Transfer: Bulk
Function Primary Log
Interface 6
Abstract Control Model
EndPoint
Transfer: Interrupt
Interface 7
Data
EndPoint
Transfer: Bulk
EndPoint
Transfer: Bulk
Function SAP
Ethernet Networking Control Model
EndPoint
Transfer: Interrupt
Function Ethernet
Interface 8
Interface 9
Data On / Off
EndPoint
Transfer: Bulk
EndPoint
Transfer: Bulk
Figure 39: LISA-U2 series end-points summary for the default and alternative USB profile configuration
☞
For more details on the configuration of the USB interface of LISA-U2 modules, see the u-blox AT
commands manual
, +UUSBCONF AT command.