Temperature Sensor - 1
Parameter No. 0x21 (33)
Name Temperature Report Unit
Info Configure reporting temperature unit
Properties Size 1 Byte Min Value 0x00 (0)
Format Enumerated Max Value 0x02 (2)
Read only False Default Value 0x02 (2)
Altering capabilities False Advanced False
Description Configure Temperature Unit report. The default Unit is depended on Regional Frequency Setting. (By default,
US=°F and EU=°C)
Value Function
0x00 (0) Disable Auto Temperature Report
0x01 (1) Report Celsius °C unit
0x02 (2) * Default Value Report Fahrenheit °F unit
Parameter No. 0x22 (34)
Name Temperature Threshold Change
Info Temperature threshold to auto report
Properties Size 2 Bytes Min Value 0x0000 for °C / 0x0100 for °F
Format Unsigned Integer Max Value 0x00FF for °C / 0x01FF for °F
Read only False Default Value 0x0001 = 1°C / 0x0104 = 4 °F
Altering capabilities False Advanced False
Description Configure Temperature threshold changed and send auto report
Value Function
0x0000 ~ 0x00FF Higher Byte set to x0 represents Celsius °C unit
0x0100 ~ 0x01FF Higher Byte set to x1 represents Fahrenheit °F unit
Parameter No. 0x23 (35)
Name Temperature Report Offset
Info Configure reporting temperature offset
Properties Size 2 Bytes Min Value 0x0000 for °C / 0x0100 for °F
Format Unsigned Integer Max Value 0x10FF for °C / 0x11FF for °F
Read only False Default Value 0x0000 = 0°C / 0x0100 = 0 °F
Altering capabilities False Advanced False
Description Configure Temperature Offset degree; Higher byte 0x = Positive degree and 1x= Negative degree
Value Function
0x0000 ~ 0x10FF 0x0000~0x00FF, (0~+255); Higher Byte 00 = Positive Celsius “+°C” e.g. 0x0002 = +2°C
0x1000~0x10FF, (-0~-255); Higher Byte 10 = Negative Celsius “-°C” e.g. 0x1002 = -2°C
0x0100 ~ 0x11FF 0x0100~0x01FF, (0~+255); Higher Byte 01=Positive Fahrenheit “+°F” e.g. 0x010A = +10°F
0x1100~0x11FF, (-0~-255); Higher Byte 10=Negative Fahrenheit “-°F” e.g. 0x110A = -10°F
Parameter No. 0x24 (36)
Name Overheat Trigger Value
Info Configure overheat report trigger value
Properties Size 2 Bytes Min Value 0x0000 for °C / 0x0100 for °F
Format Unsigned Integer Max Value 0x00FF for °C / 0x01FF for °F
Read only False Default Value 0x0028=40°C / 0x0168=104 °F
Altering capabilities False Advanced False
Description Configure Overheat report trigger value. “Higher byte 0x00 represents Celsius °C unit, 0x01 represents
Fahrenheit °F unit
Value Function
0x0000 ~ 0x00FF
From 0°C to 255°C
0x0100 ~ 0x01FF
From 0°F to 255°F
Parameter No.
0x25 (37)
Name Overheat Recover value
Info Configure overheat recover report value
Properties
Size
2 Bytes
Min Value
0x0000 for °C / 0x0100 for °F
Format
Unsigned Integer
Max Value
0x00FF for °C / 0x01FF for °F
Read only
False
Default Value
0x001E = 30°C / 0x0156 = 86°F
Altering capabilities False
Advanced
False
Description
Configure Overheat Recover
Value
Value
Function
0x0000 ~ 0x00FF
From 0°C to 255°C
0x0100 ~ 0x01FF
From 0°F to 255°F
Temperature Sensor - 2
Parameter No. 0x26 (38)
Name Association Group 4 Overheat Trigger
Info Overheat Trigger SET value
Properties Size 1 Byte Min Value 0x00 (0)
Format Enumerated Max Value 0x02 (2)
Read only False Default Value 0x00 (0)
Altering capabilities False Advanced False
Description Configure Overheat Trigger Value in Association Group 4
Value Function
0x00 (0) * Default Value Disable Basic Set (Send nothing)
0x01 (1) Send Basic ON (0xFF)
0x02 (2)
Send Basic OFF (0x00)
Parameter No. 0x27 (39)
Name Association Group 4 Overheat Cancel
Info Overheat Cancellation SET value
Properties Size 1 Byte
Min Value 0x00 (0)
Format Enumerated
Max Value 0x02 (2)
Read only False Default Value 0x00 (0)
Altering capabilities False Advanced False
Description Configure Overheat Cancellation SET value
Value Function
0x00 (0) * Default Value Disable Basic Set (Send Nothing)
0x01 (1) Send Basic ON (0x0FF)
0x02 (2) Send Basic OFF (0x00)
Parameter No. 0x28 (40)
Name Freeze Trigger Value
Info Configure Freeze Trigger Report value
Properties Size 2 Bytes Min Value 0x0000 for °C / 0x0100 for °F
Format Unsigned Integer Max Value 0x00FF for °C / 0x01FF for °F
Read only False Default Value 0x0000=0°C / 0x0120=32 °F
Altering capabilities False Advanced False
Description Configure Freeze Trigger Report Value
Value Function
0x0000 ~ 0x00FF From 0°C to 255°C
0x0100 ~ 0x01FF From 0°F to 255°F
Parameter No. 0x29 (41)
Name Freeze Recover Value
Info Configure Freeze Recover Report Value
Properties Size 2 Byte
s
Min Value 0x0000 for °C / 0x0100 for °F
Format Unsigned Integer Max Value 0x00FF for °C / 0x01FF for °F
Read only False Default Value
0x0002=2°C / 0x0124=36 °F
Altering capabilities False Advanced
False
Description Configure Freeze Recover Report Value
Value Function
0x0000 ~ 0x00FF
From 0°C to 255°C
0x0100 ~ 0x01FF From 0°F to 255°F
Parameter No. 0x2A (42)
Name Freeze Detection Valve Control
Info Configure Valve Control during freeze
Properties Size 1 Byte
Min Value 0x00 (0)
Format Enumerated
Max Value 0x01 (1)
Read only False Default Value 0x01 (1)
Altering capabilities False Advanced False
Description Enable / Disable Valve Control during Freeze when Water Leak is detected “Detected by built-in temperature
sensor. Refer to Configuration CC parameter 0x28 (41) & 0x29 (42)
Value Function
0x00 (0)
Ignore / Allowed to control Water Valve during Freeze detection
0x01 (1) * Default Value Forbidden to control Water Valve during Freeze detection
Parameter No. 0x2B (43)
Name Association Group 5 Freeze Trigger
Info Configure Freeze Trigger SET value
Properties Size 1 Byte Min Value 0x00 (0)
Format Enumerated
Max Value 0x02 (2)
Read only False Default Value 0x00(0)
Altering capabilities False Advanced False
Description Configure Association Group 5 Freeze Detection Trigger Basic Set value
Value Function
0x00 * Default Value Disable Basic Set (Send nothing)
0x01 Basic Set ON (0xFF)
0x02 Basic Set OFF (0x00)
Parameter No. 0x2C (44)
Name Association Group 5 Freeze Cancel
Info Freeze Cancellation SET value
Properties Size 1 Byte Min Value 0x00 (0)
Format Enumerated Max Value 0x02 (2)
Read only False Default Value 0x00 (0)
Altering capabilities False Advanced False
Description Configure Association Group 5 Freeze Detection Cancellation Basic Set value
Value Function
0x00 (0) * Default Value Disable Basic Set (Send nothing)
0x01 (1) Basic Set ON (0xFF)
0x02 (2)
Basic Set OFF (0x00)