 Temperature Sensor - 1 

Parameter No.   0x21 (33) 

Name                  Temperature Report Unit 

Info                      Configure reporting temperature unit 

Properties           Size                                     1 Byte                         Min Value          0x00 (0) 

                             Format                               Enumerated               Max Value          0x02 (2) 

                            Read only                            False                         Default Value     0x02 (2)

                            Altering capabilities           False                         Advanced            False 

Description        Configure Temperature Unit report. The default Unit is depended on Regional Frequency Setting. (By default, 
                            US=°F and EU=°C) 

                              Value                                    Function 

                             0x00 (0)                                Disable Auto Temperature Report 

                             0x01 (1)                                Report Celsius °C unit 

                            0x02 (2) * Default Value      Report Fahrenheit °F unit 

Parameter No.  0x22 (34) 

Name                  Temperature Threshold Change 

Info                      Temperature threshold to auto report 

Properties          Size                                     2 Bytes                   Min Value               0x0000 for °C / 0x0100 for °F 

                             Format                              Unsigned Integer    Max Value             0x00FF for °C / 0x01FF for °F 

                            Read only                          False                        Default Value        0x0001 = 1°C / 0x0104 = 4 °F 

                             Altering capabilities         False                        Advanced              False 

Description        Configure Temperature threshold changed and send auto report 

                             Value                                           Function 

                             0x0000 ~ 0x00FF              Higher Byte set to x0 represents Celsius °C unit 

                             0x0100 ~ 0x01FF              Higher Byte set to x1 represents Fahrenheit °F unit

                                                                            

Parameter No.   0x23 (35) 

Name                 Temperature Report Offset

Info                     Configure reporting temperature offset 

Properties          Size                                     2 Bytes                    Min Value          0x0000 for °C / 0x0100 for °F

                           Format                           Unsigned Integer        Max Value          0x10FF for °C / 0x11FF for °F

                           Read only                            False                       Default Value     0x0000 = 0°C / 0x0100 = 0 °F

                           Altering capabilities           False                        Advanced            False 

Description       Configure Temperature Offset degree; Higher byte 0x = Positive degree and 1x= Negative degree 

                            Value                                    Function 

                           0x0000 ~ 0x10FF         0x0000~0x00FF, (0~+255); Higher Byte 00 = Positive Celsius “+°C” e.g. 0x0002 = +2°C

                                

     

 

 0x1000~0x10FF, (-0~-255); Higher Byte 10 = Negative Celsius “-°C” e.g. 0x1002 = -2°C

                             

              

  0x0100 ~ 0x11FF        0x0100~0x01FF, (0~+255); Higher Byte 01=Positive Fahrenheit “+°F” e.g. 0x010A = +10°F

                                                                 0x1100~0x11FF, (-0~-255); Higher Byte 10=Negative Fahrenheit “-°F” e.g. 0x110A = -10°F

Parameter No.  0x24 (36) 

Name                  Overheat Trigger Value

Info                      Configure overheat report trigger value

Properties          Size                                     2 Bytes                   Min Value           0x0000 for °C / 0x0100 for °F 

                             Format                          Unsigned Integer      Max Value            0x00FF for °C / 0x01FF for °F 

                            Read only                          False                       Default Value     0x0028=40°C / 0x0168=104 °F

                            Altering capabilities         False                        Advanced           False 

Description        Configure Overheat report trigger value. “Higher byte 0x00 represents Celsius °C unit, 0x01 represents 

                

Fahrenheit °F unit

                             Value                              Function 

                

0x0000 ~ 0x00FF 

    

From 0°C to 255°C 

                

0x0100 ~ 0x01FF 

    

From 0°F to 255°F 

Parameter No. 

 

0x25 (37) 

Name                  Overheat Recover value 

Info                     Configure overheat recover report value 

Properties 

      

Size 

            

      

  

2 Bytes 

            

Min Value 

       

 0x0000 for °C / 0x0100 for °F 

                

Format 

         

         Unsigned Integer 

    

Max Value 

       

0x00FF for °C / 0x01FF for °F 

                

Read only 

      

            False 

            

Default Value 

      

0x001E = 30°C / 0x0156 = 86°F

                

Altering capabilities       False 

             

Advanced 

        

False 

Description 

   

Configure Overheat Recover

 

Value 

               

Value  

               

 Function

 

               

0x0000 ~ 0x00FF 

    

From 0°C to 255°C 

               

0x0100 ~ 0x01FF 

    

From 0°F to 255°F

                                                                            

Temperature Sensor - 2

Parameter No.   0x26 (38)

Name                  Association Group 4 Overheat Trigger

Info                      Overheat Trigger SET value

Properties           Size                                     1 Byte                         Min Value          0x00 (0) 

                             Format                               Enumerated               Max Value          0x02 (2) 

                            Read only                            False                         Default Value     0x00 (0)

                            Altering capabilities           False                         Advanced            False 

Description        Configure Overheat Trigger Value in Association Group 4

                              Value                                    Function 

                             0x00 (0) * Default Value     Disable Basic Set (Send nothing)

                             0x01 (1)                               Send Basic ON (0xFF)

                            0x02 (2) 

                 

 Send Basic OFF (0x00)

Parameter No.  0x27 (39)

Name                  Association Group 4 Overheat Cancel

Info                      Overheat Cancellation SET value

Properties          Size                                    1 Byte

   

                  Min Value               0x00 (0)

                             Format                              Enumerated   

      

Max Value             0x02 (2)

                            Read only                          False                        Default Value         0x00 (0)

                             Altering capabilities         False                        Advanced               False 

Description        Configure Overheat Cancellation SET value

                                       Value                         Function 

                             0x00 (0) * Default Value  Disable Basic Set (Send Nothing) 

                             0x01 (1)                             Send Basic ON (0x0FF) 

                            0x02 (2)                               Send Basic OFF (0x00) 

Parameter No.  0x28 (40) 

Name                   Freeze Trigger Value 

Info                      Configure Freeze Trigger Report value 

Properties             Size                                 2 Bytes                         Min Value           0x0000 for °C / 0x0100 for °F 

                               Format                            Unsigned Integer        Max Value          0x00FF for °C / 0x01FF for °F 

                              Read only                         False                          Default Value      0x0000=0°C / 0x0120=32 °F 

                             Altering capabilities         False                          Advanced            False 

Description          Configure Freeze Trigger Report Value 

                              Value                                     Function 

                             0x0000 ~ 0x00FF               From 0°C to 255°C 

                             0x0100 ~ 0x01FF               From 0°F to 255°F

                                                                            

Parameter No.   0x29 (41)

Name                  Freeze Recover Value

Info                      Configure Freeze Recover Report Value

Properties           Size                                    2 Byte

s

                         Min Value          0x0000 for °C / 0x0100 for °F

                             Format                               Unsigned Integer        Max Value         0x00FF for °C / 0x01FF for °F

                            Read only                            False                         Default Value     

 

0x0002=2°C / 0x0124=36 °F

                            Altering capabilities           False                         Advanced            

 

False 

Description        Configure Freeze Recover Report Value

                              Value                                    Function 

                             0x0000 ~ 0x00FF     

      

From 0°C to 255°C

                             0x0100 ~ 0x01FF                From 0°F to 255°F

Parameter No.  0x2A (42)

Name                  Freeze Detection Valve Control

Info                     Configure Valve Control during freeze

Properties          Size                                    1 Byte

   

                  Min Value               0x00 (0)

                             Format                              Enumerated   

      

Max Value             0x01 (1)

                            Read only                          False                        Default Value         0x01 (1)

                             Altering capabilities         False                        Advanced               False 

Description        Enable / Disable Valve Control during Freeze when Water Leak is detected “Detected by built-in temperature 

                

sensor. Refer to Configuration CC parameter 0x28 (41) & 0x29 (42)

                                       Value                         Function 

                            0x00 (0) 

                

Ignore / Allowed to control Water Valve during Freeze detection

                            0x01 (1) * Default Value   Forbidden to control Water Valve during Freeze detection

Parameter No. 0x2B (43)

Name                   Association Group 5 Freeze Trigger

Info                      Configure Freeze Trigger SET value

Properties             Size                                  1 Byte                         Min Value            0x00 (0)

                               Format                              Enumerated 

    

      Max Value          0x02 (2)

                              Read only                           False                        Default Value      0x00(0)

                             Altering capabilities           False                          Advanced           False 

Description          Configure Association Group 5 Freeze Detection Trigger Basic Set value

                              Value                                     Function 

                             0x00 * Default Value             Disable Basic Set (Send nothing)

                             0x01                                        Basic Set ON (0xFF) 

                             0x02                                        Basic Set OFF (0x00)

                                                    
Parameter No.   0x2C (44)

Name                  Association Group 5 Freeze Cancel

Info                      Freeze Cancellation SET value

Properties           Size                                     1 Byte                         Min Value          0x00 (0) 

                             Format                               Enumerated               Max Value          0x02 (2) 

                            Read only                            False                         Default Value     0x00 (0)

                            Altering capabilities           False                         Advanced            False 

Description        Configure Association Group 5 Freeze Detection Cancellation Basic Set value

                              Value                                    Function 

                             0x00 (0) * Default Value     Disable Basic Set (Send nothing)

                             0x01 (1)                               Basic Set ON (0xFF)

                            0x02 (2) 

                 

 Basic Set OFF (0x00)

Summary of Contents for BVSZWU

Page 1: ...op of the handle of ball valve 1 2 1 2 If you are installing the Ball Valve Servo outdoor you may consider to disable the touch sensing button to prevent it activated from rain drops or pets To Disabl...

Page 2: ...8 3 Turn Valve to CLOSE 8 4 Pause OPEN CLOSE Operation 8 5 Resume OPEN CLOSE Operation 9 WATER LEAK ALARM 9 1 Water Leak Detection Alarm 9 2 Water Leak Alarm Cancellation 10 TEMPERATURE SENSOR 11 Z W...

Page 3: ...Built in temperature sensor Visual indicators 3 Colors LED with green yellow red Touch sense button Network water valve and alarm operations Knob Use to adjust Clamp widths DSK label Z Wave SmartStart...

Page 4: ...eep sounds for 2 seconds Factory Default Reset will a Remote the BVS from Z Wave Network b Delete the association setting c Restore the con guration settings to the default 8 WATER VALVE OPERATION Cal...

Page 5: ...SECURITY_2 1 Support Support Support Support SUPERVISION 1 Support Support Support Support FIRMWARE_UPDATE_MD 5 Support Support Support Support SENSOR_MULTILEVEL Temperature 11 Support Support Suppor...

Page 6: ...ties False Advanced False Description Con gure Noti cation Report in Association Group 1 Lifeline Set Bit to 0 Disable Set Bit to 1 Enable Value Function Bit 0 Water Valve Open Close 0 Disable 1 Enabl...

Page 7: ...0 Format Enumerated Max Value 0x02 2 Read only False Default Value 0x00 0 Altering capabilities False Advanced False Description Con gure Overheat Trigger Value in Association Group 4 Value Function 0...

Page 8: ...x71 113 Name Battery Threshold Change Report Info Set Battery Threshold Level Change Properties Size 1 Byte Min Value 0x00 0 Format Unsigned Max Value 0x63 99 Read only False Default Value 0x0A 10 Alt...

Page 9: ...replace the defective or damaged parts of the Product Normal wear and tear is not covered nor is abnormal use misuse mishandling faulty installation improper shipping damage caused by disasters such a...

Reviews: