background image

2.1 What'

s

 

Z

-

Wave?

2.2 Custos 

BVS

3.1 

Physical 

Specifications

Model 

No.

BVSZWU (

US

)/ 

BVSZWE

 (

EU

)

Dimensions

14.8

x

9

.

6

x

13

.

3mm

Weight

BVS Unit: 603g

Body 

Color

White

Knob 

Color

Blue

Waterproof & 

Dustproof

IP66 level / outdoor deployment

Usage

For Indoor and Outdoor Water Valve On/Off

Operation Temperature

(14~122 

℉) (-

10~+50

℃)

Relative 

Humidity

8%~

80

%

3.2 

Hardware 

Specifications

Z-Wave 

Module

ZGM130S037HGN

2R

Z-Wave 

RF

 

Distance

40m/

131inch

 (Indoor) /

140m

/

459inch

(

Outdoor)

Region 

Frequency

US: 

908

.

4

 & 916MHz FCC CFR47 Part 15.249 EU: 868.42 & 869.85MHz

Motor 

Torque

 

Power

Adaptive 

torque output max: 8n.m

Water 

Leak

 

Sensor

Local 

Water Leak Sensor Probe

Temperature 

Sensor

Built-in 

temperature sensor, Range from -40°C to +125°C / (-40°F to +257°F)

Action 

Button

Touch 

Sense Button x 1

LED & 

Sound

 

Indicator

colors LED. (Green, Yellow & Red); Buzzer (Max. 85dB)

Power 

Supply

AC-DC: 

AC (110V 60Hz / 220V 50Hz); DC (12V / 1A)

Power 

Consumption

Standby: ~

10mA@12VDC=0.12W Full Operation: Max~700mA@12VDC=8.4W

1 REVISION HISTORY

Date: 4-Aug-2020
SW Rev: V3.06
Description: 
1. Water Alarm Cancellation – Change to 1 short click from 2 short click 
2. Water Alarm Timeout – Water Leak Alarm UI 30 seconds timeout before BVS 
physical installation is triggered. 
3. Leak Sensor Detection – Extended to 1 second detecting time from 10ms
Section: UI / Operation / Logic

2 INTRODUCTION

Z-Wave is international wireless protocol used for Smart Home. It’s a mesh 
network technology to ensure reliable two-way communication with each other. 
Z-Wave provides interoperability and security from multi-vendors to make sure 
Certified Products work within any Z-Wave network.

Custos Ball Valve Servo “Custos BVS” is capable for outdoor deployment for 
controlling quarter turn water valve OPEN / CLOSE. It also supports auto CLOSE 
valve when water leak is detected by Local Leak Sensor Probe. Custos BVS can 
be operated in any Z-Wave network with other Z-Wave certified gateways or 
devices from other manufacturers. All mains operated nodes within the network 
will act as signal repeater regardless of vendor to increase reliability of the 
network.

Sound indicator 

Buzzer

Temperature 

sensor

Built-in temperature sensor

Visual indicators

3 Colors LED with green, yellow & red

Touch sense button

Network, water valve and alarm operations

Knob

Use to adjust Clamp widths

DSK label

Z-Wave “SmartStart” and product label

2.3 

Connectors

 & Interfaces

Serial number

Serial number label 

Clamp

Clamp on water pipe. Max 1-1/4 inch

Driving

 fork

Couple with valve handle

Power connector

DC 12V / 1A in

Dust cover

Prevent Dust and Water

Leak sensor connector

Local leak sensor probe 

FCC ID: 2AUZX-BVSZWU

DC12V      1A

BVSZWU US908.4/916Mhz

Assembled in China

S/N:000212030009012

Ball Valve Servo

Designed by

IP66

48267

Device Specific Key

IC ID: 26714-BVSZWU

a

c

d

e

f

g

h

j

k

l

b

Type A

Type B

Depend on region and valve types there 
are 2 types of driving forks

i

Driving fork

4 WORKING MODE & FEATURES

4.1

 

Standalone 

Support Water Valve Operation, Water Leak detection & Alarm, Inclusion, 

Exclusion and Factory Default Reset. 
- By default, Custos BVS is in Standalone Mode with Factory Default Setting and 
it’s not belonged to any Z-Wave Mesh Network. 
- End user can enjoy all regular functions without Z-Wave benefit. Such as Water 
Valve, Leak detection by Local Leak Sensor Probe.

4.2 Mesh Network

Support SmartStart, Classic Inclusion, Exclusion & Factory Default Reset. 

- After Adding Custos BVS to a Z-Wave Mesh Network, end-customer can fully 
enjoy all functions, such as remote control, associate with other Z-Wave end 
devices…

4.3 Ball Valve Actuator 

4.4 Water Leak Sensor & Alarm

4.5 Ambient Temperature Sensor

Support OPEN, CLOSE, PAUSE 

- RESUME during OPEN/CLOSE operation. 
- Manual Calibration position of valve handle. (Only support operate by Touch 
Sense Button) 
- Water Valve will be closed automatically once Local Water Leak Sensor Probe 
is triggered. 
- Water Valve can be triggered with associated other Z-Wave end-devices. (Only 
in Mesh Network Mode)

Water Leak Alarm will be activated and to CLOSE Water Valve automatically 

once Local Water Leak is detected. 
- Once Local Water Leak is detected then BVS will also send out Water Leak 
Alarm with no location support to Z-Wave

 

Gateway. (Only in Mesh Network 

Mode)

By default, BVS sends temperature report automatically to gateway when every 

1°C or 1.8°F degree changed. (Only in Mesh Network Mode).

a

c

d
e

f

g

h

j

k

l

b

i

PAGE 1

  Ubitech Ltd.                                                                                                                                                                                                                                                Version: 3.0

3 FEATURES & SPECIFICATIONS

Summary of Contents for BVSZWU

Page 1: ...op of the handle of ball valve 1 2 1 2 If you are installing the Ball Valve Servo outdoor you may consider to disable the touch sensing button to prevent it activated from rain drops or pets To Disabl...

Page 2: ...8 3 Turn Valve to CLOSE 8 4 Pause OPEN CLOSE Operation 8 5 Resume OPEN CLOSE Operation 9 WATER LEAK ALARM 9 1 Water Leak Detection Alarm 9 2 Water Leak Alarm Cancellation 10 TEMPERATURE SENSOR 11 Z W...

Page 3: ...Built in temperature sensor Visual indicators 3 Colors LED with green yellow red Touch sense button Network water valve and alarm operations Knob Use to adjust Clamp widths DSK label Z Wave SmartStart...

Page 4: ...eep sounds for 2 seconds Factory Default Reset will a Remote the BVS from Z Wave Network b Delete the association setting c Restore the con guration settings to the default 8 WATER VALVE OPERATION Cal...

Page 5: ...SECURITY_2 1 Support Support Support Support SUPERVISION 1 Support Support Support Support FIRMWARE_UPDATE_MD 5 Support Support Support Support SENSOR_MULTILEVEL Temperature 11 Support Support Suppor...

Page 6: ...ties False Advanced False Description Con gure Noti cation Report in Association Group 1 Lifeline Set Bit to 0 Disable Set Bit to 1 Enable Value Function Bit 0 Water Valve Open Close 0 Disable 1 Enabl...

Page 7: ...0 Format Enumerated Max Value 0x02 2 Read only False Default Value 0x00 0 Altering capabilities False Advanced False Description Con gure Overheat Trigger Value in Association Group 4 Value Function 0...

Page 8: ...x71 113 Name Battery Threshold Change Report Info Set Battery Threshold Level Change Properties Size 1 Byte Min Value 0x00 0 Format Unsigned Max Value 0x63 99 Read only False Default Value 0x0A 10 Alt...

Page 9: ...replace the defective or damaged parts of the Product Normal wear and tear is not covered nor is abnormal use misuse mishandling faulty installation improper shipping damage caused by disasters such a...

Reviews: