background image

PAGE 4

  Ubitech Ltd.                                                                                                                                                                                                                                                Version: 3.0

11.10 Configuration CC

Note: No Bulk Support equals

 

to True. It will return an Application Rejected Request Command 

when receiving Configuration Bulk Set or Get (if received without Supervision encapsulation). It 
will reset all its configuration parameters if either manually reset to factory default or receives a 
Configuration Default Reset Command. It will NOT modify or reset any configuration parameter 
when being included or excluded of a Z-Wave network.

                                                                                      

   

User Interface

Parameter No.   0x41 (65)

Name                  Buzzer

Info                      Enable / Disable Buzzer

Properties           Size                                    1 Byte                          Min Value           0x00 (0)

                             Format                               Enumerated                 Max Value         0x01 (1)

                            Read only                            False                         Default Value     

 

0x01 (1)

                            Altering capabilities           False                         Advanced            

 

False 

Description        Enable / Disable Built-in Buzzer Sound

                              Value                                    Function 

                             0x00 (0)   

      

                  Disable Buzzer

                            0x01 (1) * Default Value      Enable Buzzer

Parameter No.  0x42 (66)

Name                  LED Brightness Level

Info                     Configure LED Brightness Level 

Properties          Size                                    1 Byte

   

                  Min Value               0x00 (0%)

                             Format                              Unsigned Integer  

  

Max Value             0x63 (99%)

                            Read only                          False                        Default Value         0x50 (80%)

                             Altering capabilities         False                        Advanced               False 

Description       Configure Built-in LED Brightness Level

                             Value                                   Function 

                          

 

0x00 ~ 0x63

              

0% ~ 99%

Parameter No. 

  

0x43 (67)

Name                  Touch Keylock Protection

Info                      Disable / Enable Touch Keylock Protection

Properties             Size                                  1 Byte                         Min Value            0x00 (0)

                               Format                              Enumerated 

    

      Max Value          0x01 (1)

                              Read only                           False                        Default Value      0x01(0)

                             Altering capabilities           False                          Advanced           False 

Description       

 

Disable / Enable Touch Keylock Protection

                              Value                                     Function 

                            0x00 (0) * Default Value    Disable Keylock Protection

                           

 

0x01 (1) 

                

Enable Keylock Protection

                                                                                      

  

Notification Report

Parameter No.   0x51 (81)

Name                  Notification Report Lifeline

Info                      Configure Notification Report (Bitmask)

Properties           Size                                    1 Byte                          Min Value           0x00 (0)

                             Format                               Bit Field                

    

Max Value        

 

0x0F (15)

                            Read only                            False                         Default Value     

 

0x0D (13)

                            Altering capabilities           False                         Advanced            

 

False 

Description        Configure Notification Report in Association Group 1 Lifeline “Set Bit to 0 = Disable, Set Bit to 1 = Enable”

                              Value                                    Function 

                             Bit 0  

      

                 

    

 Water Valve Open / Close – 0 = Disable / *1 = Enabled

                           

 

Bit 1                                      Overheat Detection – *0=Disable / 1=Enable

  

               

Bit 2

   

                                Freeze Detection – 0=Disable / *1 = Enable

               

              

        

Bit 3

 

                                   Local Water Leak Sensor Probe Detection – 0=Disable / *1=Enable

 

                                                                            

  

Water Valve 

Parameter No.  0x11 (17) 

Name                 Inverse Water Valve Report 

Info                     Inverse Switch Binary Report value 

Properties         Size                                    1 Byte                 Min Value           0x00 (0) 

                           Format                               Enumerated       Max Value          0x01 (1) 
                   
                           Read only                          False                  Default Value     0x01 (1) 

                           Altering capabilities         False                   Advanced           False 

Description       Inverses Switch Binary Report when Water Valve = 0x00 “Valve doesn’t let the water run through in                 
                           Notification and real physical status.” 

                           Value                                  Function 

                           0x00 (0)                              Disable: 0x00 = does not let water run through, 0xFF = let water run through. 
                                                                       Based on Configuration CC setting 0x12 & 0x13 

                           0x01 (1) * Default Value   Enable: 0x00 = let water run through, 0xFF = does not let water run through
                                                                       Based on Configuration CC setting 0x12 & 0x13 

Parameter No.  0x12 (18) 

Name                  Association Group 2 SET Value 

Info                     Valve SET Value when receives 0xFF

Properties          Size                                    1 Byte                Min Value          0x00 (0) 

                            Format                                Enumerated     Max Value         0x02 (2) 

                            Read only                           False                Default Value    0x01 (1) 

                            Altering capabilities          False                 Advanced          False 

 Description       Configure Association Group 2 Basic Set value when Binary Switch Report = 0xFF *(Related to 
                            Configuration setting 0x11) 

                           Value                                   Function 

                           0x00 (0)                             Disable Basic Set (Send nothing) 

                           0x01 (1) * Default Value   Basic ON (0xFF) 

                           0x02 (2)                              Basic OFF (0x00)

                                           
 Parameter No.  0x13 (19) 

 Name                   Association Group 2 SET Value 

 Info                      Valve SET Value when receives 0x00 

 Properties 
                                Size                                 1 Byte               Min Value         0x00 (0) 
                             
                             Format                               Enumerated     Max Value        0x02 (2) 

                             Read only                          False                Default Value    0x02 (2) 

                             Altering capabilities         False                Advanced          False 

 Description        Configure Association Group 2 Basic Set value when Binary Switch Report = 0x00 *(Related to Configuration         
                             setting 0x11) 

                               Value                                Function 

                             0x00 (0)                              Disable Basic Set (Send nothing) 

                             0x01 (1)                              Basic ON (0xFF) 

                            0x02 (2) * Default Value    Basic OFF (0x00)

Summary of Contents for BVSZWU

Page 1: ...op of the handle of ball valve 1 2 1 2 If you are installing the Ball Valve Servo outdoor you may consider to disable the touch sensing button to prevent it activated from rain drops or pets To Disabl...

Page 2: ...8 3 Turn Valve to CLOSE 8 4 Pause OPEN CLOSE Operation 8 5 Resume OPEN CLOSE Operation 9 WATER LEAK ALARM 9 1 Water Leak Detection Alarm 9 2 Water Leak Alarm Cancellation 10 TEMPERATURE SENSOR 11 Z W...

Page 3: ...Built in temperature sensor Visual indicators 3 Colors LED with green yellow red Touch sense button Network water valve and alarm operations Knob Use to adjust Clamp widths DSK label Z Wave SmartStart...

Page 4: ...eep sounds for 2 seconds Factory Default Reset will a Remote the BVS from Z Wave Network b Delete the association setting c Restore the con guration settings to the default 8 WATER VALVE OPERATION Cal...

Page 5: ...SECURITY_2 1 Support Support Support Support SUPERVISION 1 Support Support Support Support FIRMWARE_UPDATE_MD 5 Support Support Support Support SENSOR_MULTILEVEL Temperature 11 Support Support Suppor...

Page 6: ...ties False Advanced False Description Con gure Noti cation Report in Association Group 1 Lifeline Set Bit to 0 Disable Set Bit to 1 Enable Value Function Bit 0 Water Valve Open Close 0 Disable 1 Enabl...

Page 7: ...0 Format Enumerated Max Value 0x02 2 Read only False Default Value 0x00 0 Altering capabilities False Advanced False Description Con gure Overheat Trigger Value in Association Group 4 Value Function 0...

Page 8: ...x71 113 Name Battery Threshold Change Report Info Set Battery Threshold Level Change Properties Size 1 Byte Min Value 0x00 0 Format Unsigned Max Value 0x63 99 Read only False Default Value 0x0A 10 Alt...

Page 9: ...replace the defective or damaged parts of the Product Normal wear and tear is not covered nor is abnormal use misuse mishandling faulty installation improper shipping damage caused by disasters such a...

Reviews: