11
.
6 Indicator CC
Basic CC Map to CC Value
Basic Set Binary Switch Set 0x00 = ON / Water Valve OPEN (Valve lets water run through)
0xFF = OFF / Water Valve CLOSE (Valve doesn’t let water run through)
Basic Report Binary Switch Report 0x00 = ON / Water Valve OPEN (Valve lets water run through)
0xFF = OFF / Water Valve CLOSE (Valve doesn’t let water run through)
Parameter Value
Indicator ID 0x50 = (Node Identify)
Property ID 0x03 = (On/Off Periods)
0x04 = (On/Off Cycles)
0x05 = (On time within an On/Off period)
11
.
7 Basic CC Mapping of Water Valve
11
.
8 Association Group Info (AGI)
Association
Group Name Node Function
1 Lifeline 5 -Device Reset Locally Notification
-Basic Report
-Binary Switch Report
-Indicator Report
-Sensor Multilevel Report–Temperature “Auto report based on Configuration Parameter 0x22 Setting.”
-Heat Alarm Notification Report (0x04)
-0x00 = State idle
-0x02 = Overheat – no location support
-0x06 = Underheat – no location support
-Water Alarm Notification Report (0x05)
-0x00 = State idle
-0x02 = Water leak detected – no location support
-Water Valve Notification Report (0x0F)
-0x01 = Valve operation
0x00 = VALVE CLOSED/OFF (Valve does not let the water run through.)
0x01 = VALVE OPEN/ON (Valve lets the water run through)
2 Water Valve 5 -Basic Set(By default the Configuration CC parameter 0x11 (17)
“Inverse Water Valve report” is enabled to send out following report.)
-0x00 = Let the water run through (Based on Configuration Parameter 0x13)
-0xFF = Doesn’t let the water run through. (Based on Configuration Parameter 0x12)
3 Leak Sensor 5 -Basic Set
-0x00 = IDLE / CANCEL (Based on Configuration Parameter 0x32 Setting)
-0xFF = TRIGGERED (Based on Configuration Parameter 0x31 Setting)
4 Overheat 5 -Basic Set Alarm
-0x00 = IDLE / CANCEL (Based on Configuration Parameter 0x27 Setting)
-0xFF = TRIGGERED (Based on Configuration Parameter 0x26 Setting)
5 Freeze Alarm 5 - Basic Set
-0x00 = IDLE / CANCEL (Based on Configuration Parameter 0x2C Setting)
11.9 Supported Command Classes IN NIF
Command
Class
Version
Not Added
A
dded
Security 0
Added
Security 2
Added
ZWAVEPLUS_INFO
2
Support
Support
Support
---
Support
----
SWITCH_BINARY
2
Support
Support
---
Support
---
Support
ASSOCIATION
3
Support
Support
---
Support
---
Support
MULTI_CHANNEL_ASSOCIATION
4
Support
Support
---
Support
---
Support
ASSOCIATION_GRP_INFO
3
Support
Support
---
Support
---
Support
NOTIFICATION
8
Support
Support
---
Support
---
Support
TRANSPORT_SERVICE
2
Support
Support
Support
---
Support
---
VERSION
3
Support
Support
---
Support
---
Support
MANUFACTURER_SPECIFIC
2
Support
Support
---
Support
---
Support
DEVICE_RESET_LOCALLY
1
Support
Support
---
Support
---
Support
INDICATOR
3
Support
Support
---
Support
---
Support
POWERLEVEL
1
Support
Support
---
Support
---
Support
SECURITY
1
Support
Support
Support
---
Support
---
SECURITY_2
1
Support
Support
Support
---
Support
---
SUPERVISION
1
Support
Support
Support
---
Support
---
FIRMWARE_UPDATE_MD
5
Support
Support
---
Support
---
Support
SENSOR_MULTILEVEL-
Temperature
11
Support
Support
---
Support
---
Support
CONFIGURATION
4
Support
Support
---
Support
---
Support
APPLICATION
STATUS
1
Support
Support
Support
---
Support
---
BASIC
COMMAND
2
Support
Support
Support
Support
Support
Support
BATTERY
1
Support
Support
---
Support
---
Support
PAGE 3
Ubitech Ltd. Version: 3.0
11
.
2 Z-Wave Plus Info
2
5 (ZWAVEPLUS_INFO_REPORT_ROLE_TYPE_SLAVE_ALWAYS_ON)
0 (ZWAVEPLUS_INFO_REPORT_NODE_TYPE_ZWAVEPLUS_NODE)
0x1500 (ICON_TYPE_GENERIC_VALVE_OPEN_CLOSE)
0x1500 (ICON_TYPE_GENERIC_VALVE_OPEN_CLOSE)
Role Type
Node Type
Installer Icon Type
User Icon Type
11
.
3 Version CC
Notification Type Notification Events / State Description
Heat Alarm 0x04 State idle 0x00 Notification value for the state variable going to idle (V5)
Overheat detected 0x02 No Location Support Event
Underheat detected 0x06 No Location Support Event
Water Alarm 0x05 State idle 0x00 Notification value for the state variable going to idle (V5)
Water leak detected 0x02 No Location Support Event
Water Valve 0x0F Valve operation status 0x01 Event Parameter 1 byte=
-0x00 =Valve does not let the water run through
-0x01 =Valve lets the water run through
Parameter Value
Z-Wave Protocol Library Type 0x03
Z-Wave Protocol Version 0x07
Z-Wave Protocol Sub Version 0x0D
Firmware 0 Version 0x03 – Z-Wave Chip Major Firmware Version
Firmware 0 Sub Version 0x02 – Z-Wave Chip Minor Firmware Version
Hardware Version 0x03
Number of firmware targets 0x00
11
.
4 Manufacturer Specific
Parameter Value
Manufacturer ID 1 0x02
Manufacturer ID 2 0x70
Product Type ID 1 0x01
Product Type ID 2 0x01
Product ID1 0x00
Product ID 2 0x0A
11
.
5 Notification CC
Z-Wave Plus Version
10 TEMPERATURE SENSOR
i. By default, Custos BVS will send report to Gateway automatically in 1 °C or 4°F
change of ambient temperature.
ii. Custos will send out °F in US version and °C for other versions.
11 Z-WAVE SOFTWARE DEFINITION
11.1 Software Specifications
Parameter
Value
Generic Device Type
Wireless Technology
Z-Wave Certification Type
Z-Wave SDK Version
Z-Wave Library
Z-Wave Role Type
Device Type
Specific Device Type
Security Class
SmartStart
Firmware Update
Association
Factory Default Reset
Power Down Memory
Z-Wave
Z-Wave Plus v2Certification
V7.13.2
Enhanced 232 Slave
Always On Slave
Binary Switch
Switch Binary
Specific Type Not Used
Non-Security, S0, S2 Unauthenticated and S2 Authenticated
Support: SmartStart is auto activated if it’s out of Z-Wave network when power on
Support: Firmware upgrade support via RF, “Over The Air (OTA)”
Support 5 Groups. Lifeline, Water Valve, Water Leak, Overheat & Underheat
Support: Device Locally Reset
Support: Valve ON/OFF status, Leak Alarm supportsuddenly power cut and restoreprevious status