background image

11

.

6 Indicator CC

Basic CC          Map to CC                     Value 

Basic Set         Binary Switch Set        0x00 = ON / Water Valve OPEN (Valve lets water run through) 

                                                                0xFF = OFF / Water Valve CLOSE (Valve doesn’t let water run through) 

Basic Report  Binary Switch Report  0x00 = ON / Water Valve OPEN (Valve lets water run through) 

                                                               0xFF = OFF / Water Valve CLOSE (Valve doesn’t let water run through)

Parameter                         Value 

Indicator ID                         0x50 = (Node Identify) 

Property ID                         0x03 = (On/Off Periods) 

                                             0x04 = (On/Off Cycles) 

                                             0x05 = (On time within an On/Off period)

11

.

7 Basic CC Mapping of Water Valve

11

.

8 Association Group Info (AGI)

Association
 Group               Name      Node           Function 

        1                       Lifeline           5            -Device Reset Locally Notification 
                                                                       -Basic Report 
                                                                       -Binary Switch Report 
                                                                       -Indicator Report 
                                                                       -Sensor Multilevel Report–Temperature “Auto report based on Configuration Parameter 0x22 Setting.” 
                                                                       -Heat Alarm Notification Report (0x04) 
                                                                               -0x00 = State idle 
                                                                               -0x02 = Overheat – no location support
                                                                               -0x06 = Underheat – no location support 
                                                                       -Water Alarm Notification Report (0x05) 
                                                                               -0x00 = State idle 
                                                                               -0x02 = Water leak detected – no location support 
                                                                       -Water Valve Notification Report (0x0F) 
                                                                               -0x01 = Valve operation
                                                                                             0x00 = VALVE CLOSED/OFF (Valve does not let the water run through.)
                                                                                             0x01 = VALVE OPEN/ON (Valve lets the water run through) 

      2                       Water Valve         5           -Basic Set(By default the Configuration CC parameter 0x11 (17) 
                                                                                          “Inverse Water Valve report” is enabled to send out following report.) 
                                                                               -0x00 = Let the water run through (Based on Configuration Parameter 0x13) 
                                                                               -0xFF = Doesn’t let the water run through. (Based on Configuration Parameter 0x12) 

     3                        Leak Sensor        5            -Basic Set 
                                                                               -0x00 = IDLE / CANCEL (Based on Configuration Parameter 0x32 Setting) 
                                                                               -0xFF = TRIGGERED (Based on Configuration Parameter 0x31 Setting) 

     4                        Overheat            5            -Basic Set Alarm 
                                                                               -0x00 = IDLE / CANCEL (Based on Configuration Parameter 0x27 Setting) 
                                                                               -0xFF = TRIGGERED (Based on Configuration Parameter 0x26 Setting) 

     5                       Freeze Alarm      5            - Basic Set 
                                                                               -0x00 = IDLE / CANCEL (Based on Configuration Parameter 0x2C Setting)

11.9 Supported Command Classes IN NIF

Command 

Class

Version

Not Added

A

dded

Security 0

 

Added

Security 2

 

Added

ZWAVEPLUS_INFO

2

Support

Support

Support

---

Support

----

SWITCH_BINARY

2

Support

Support

---

Support

---

Support

ASSOCIATION

3

Support

Support

---

Support

---

Support

MULTI_CHANNEL_ASSOCIATION

4

Support

Support

---

Support

---

Support

ASSOCIATION_GRP_INFO

3

Support

Support

---

Support

---

Support

NOTIFICATION

8

Support

Support

---

Support

---

Support

TRANSPORT_SERVICE

2

Support

Support

Support

---

Support

---

VERSION

3

Support

Support

---

Support

---

Support

MANUFACTURER_SPECIFIC

2

Support

Support

---

Support

---

Support

DEVICE_RESET_LOCALLY

1

Support

Support

---

Support

---

Support

INDICATOR

3

Support

Support

---

Support

---

Support

POWERLEVEL

1

Support

Support

---

Support

---

Support

SECURITY

1

Support

Support

Support

---

Support

---

SECURITY_2

1

Support

Support

Support

---

Support

---

SUPERVISION

1

Support

Support

Support

---

Support

---

FIRMWARE_UPDATE_MD

5

Support

Support

---

Support

---

Support

SENSOR_MULTILEVEL-

Temperature

11

Support

Support

---

Support

---

Support

CONFIGURATION

4

Support

Support

---

Support

---

Support

APPLICATION 

STATUS

1

Support

Support

Support

---

Support

---

BASIC 

COMMAND

2

Support

Support

Support

Support

Support

Support

BATTERY

1

Support

Support

---

Support

---

Support

PAGE 3

  Ubitech Ltd.                                                                                                                                                                                                                                                Version: 3.0

11

.

2 Z-Wave Plus Info

2

5 (ZWAVEPLUS_INFO_REPORT_ROLE_TYPE_SLAVE_ALWAYS_ON)

0 (ZWAVEPLUS_INFO_REPORT_NODE_TYPE_ZWAVEPLUS_NODE)

0x1500 (ICON_TYPE_GENERIC_VALVE_OPEN_CLOSE)

0x1500 (ICON_TYPE_GENERIC_VALVE_OPEN_CLOSE)

Role Type

Node Type

Installer Icon Type

User Icon Type

11

.

3 Version CC

   

Notification Type     Notification Events / State            Description

Heat Alarm     0x04  State idle                              0x00   Notification value for the state variable going to idle (V5) 
                                        
                                   Overheat detected              0x02   No Location Support Event 

                                   Underheat detected           0x06   No Location Support Event 

Water Alarm   0x05   State idle                            0x00   Notification value for the state variable going to idle (V5) 
                                      
                                   Water leak detected           0x02   No Location Support Event 

Water Valve    0x0F  Valve operation status       0x01   Event Parameter 1 byte=
           
                                                                                            -0x00 =Valve does not let the water run through

                                                                                            -0x01 =Valve lets the water run through

Parameter                                                Value 

Z-Wave Protocol Library Type               0x03 

Z-Wave Protocol Version                       0x07 

Z-Wave Protocol Sub Version               0x0D 

Firmware 0 Version                                 0x03 – Z-Wave Chip Major Firmware Version 

Firmware 0 Sub Version                         0x02 – Z-Wave Chip Minor Firmware Version 

Hardware Version                                   0x03 

Number of firmware targets                   0x00

11

.

4 Manufacturer Specific

Parameter                                    Value 

Manufacturer ID 1                       0x02 

Manufacturer ID 2                       0x70 

Product Type ID 1                       0x01 

Product Type ID 2                       0x01 

Product ID1                                 0x00 

Product ID 2                                0x0A

11

.

5 Notification CC

Z-Wave Plus Version

10 TEMPERATURE SENSOR

i. By default, Custos BVS will send report to Gateway automatically in 1 °C or 4°F 
change of ambient temperature. 
ii. Custos will send out °F in US version and °C for other versions.

11 Z-WAVE SOFTWARE DEFINITION

11.1 Software Specifications

Parameter

Value

Generic Device Type

Wireless Technology

Z-Wave Certification Type

Z-Wave SDK Version

Z-Wave Library

Z-Wave Role Type

Device Type

Specific Device Type

Security Class

SmartStart

Firmware Update

Association

Factory Default Reset

Power Down Memory

Z-Wave

Z-Wave Plus v2Certification

V7.13.2

Enhanced 232 Slave

Always On Slave

Binary Switch

Switch Binary

Specific Type Not Used

Non-Security, S0, S2 Unauthenticated and S2 Authenticated

Support: SmartStart is auto activated if it’s out of Z-Wave network when power on

Support: Firmware upgrade support via RF, “Over The Air (OTA)”

Support 5 Groups. Lifeline, Water Valve, Water Leak, Overheat & Underheat

Support: Device Locally Reset

Support: Valve ON/OFF status, Leak Alarm supportsuddenly power cut and restoreprevious status

Summary of Contents for BVSZWU

Page 1: ...op of the handle of ball valve 1 2 1 2 If you are installing the Ball Valve Servo outdoor you may consider to disable the touch sensing button to prevent it activated from rain drops or pets To Disabl...

Page 2: ...8 3 Turn Valve to CLOSE 8 4 Pause OPEN CLOSE Operation 8 5 Resume OPEN CLOSE Operation 9 WATER LEAK ALARM 9 1 Water Leak Detection Alarm 9 2 Water Leak Alarm Cancellation 10 TEMPERATURE SENSOR 11 Z W...

Page 3: ...Built in temperature sensor Visual indicators 3 Colors LED with green yellow red Touch sense button Network water valve and alarm operations Knob Use to adjust Clamp widths DSK label Z Wave SmartStart...

Page 4: ...eep sounds for 2 seconds Factory Default Reset will a Remote the BVS from Z Wave Network b Delete the association setting c Restore the con guration settings to the default 8 WATER VALVE OPERATION Cal...

Page 5: ...SECURITY_2 1 Support Support Support Support SUPERVISION 1 Support Support Support Support FIRMWARE_UPDATE_MD 5 Support Support Support Support SENSOR_MULTILEVEL Temperature 11 Support Support Suppor...

Page 6: ...ties False Advanced False Description Con gure Noti cation Report in Association Group 1 Lifeline Set Bit to 0 Disable Set Bit to 1 Enable Value Function Bit 0 Water Valve Open Close 0 Disable 1 Enabl...

Page 7: ...0 Format Enumerated Max Value 0x02 2 Read only False Default Value 0x00 0 Altering capabilities False Advanced False Description Con gure Overheat Trigger Value in Association Group 4 Value Function 0...

Page 8: ...x71 113 Name Battery Threshold Change Report Info Set Battery Threshold Level Change Properties Size 1 Byte Min Value 0x00 0 Format Unsigned Max Value 0x63 99 Read only False Default Value 0x0A 10 Alt...

Page 9: ...replace the defective or damaged parts of the Product Normal wear and tear is not covered nor is abnormal use misuse mishandling faulty installation improper shipping damage caused by disasters such a...

Reviews: