Pool Filter 300 - Pool Filter Set 300-2,5 m3/h
1
T
he
d
u
ration
of
the
fi
l
tration
mu
st
b
e
ada
p
ted
to
m
eet
the
s
p
ecific
w
eather
conditions
and
fre
qu
enc
y w
ith
w
hich
the
s
w
i
mm
ing
p
oo
l
is
u
sed.
D
u
ring
the
ti
m
e
of
y
ear
w
hen
the
s
w
i
mm
ing
p
oo
l
is
u
sed
,
the
fi
l
tration
s
y
ste
m mu
st
r
u
n
s
uffi
cient
ly l
ong
e
v
er
y
da
y
to
ens
u
re
at
l
east
the
co
mpl
ete
exchange/
pu
rif
y
ing
of
the
w
ater.
(2)
R
eg
ul
ar
ly
check
the
p
oo
l’
s
w
ater
l
e
v
e
l
and
the
fi
l
tering
s
y
ste
m’
s
o
p
erating
p
ress
u
re.
(3)
R
eg
ul
ar
ly
c
l
ean
the
p
re
l
i
m
inar
y
fi
l
ter
b
asket
of
the
ski
mm
er
and
the
pump
.
(4)
Be
s
u
re
to
re
pl
ace
the
si
l
ica
fi
l
ter
sand
e
v
er
y
t
w
o
y
ears.
(5)
R
e
m
o
v
ing
the
v
ac
uum
fi
l
ter.
T
he
v
ac
uum
fi
l
ter
m
a
y b
eco
m
e
da
m
aged
in
the
co
u
rse
of
its
insta
ll
ation
or
d
u
ring
u
se
after
insta
ll
ation.
T
he
m
ost
significant
,
te
ll
ta
l
e
sign
of
da
m
age
is
the
discharge
of
si
l
ica
sand
into
the
s
w
i
mm
ing
p
oo
l
.
Sho
ul
d
this
b
e
the
case
,
it
is
necessar
y
to
re
pl
ace
the
v
ac
uum
fi
l
ter.
T
he
fo
ll
o
w
ing
contains
a
descri
p
tion
of
the
p
roced
u
re::
-
R
e
m
o
v
e
the
sand
fi
l
ter.
-
Briefl
y
rinse
the
fi
l
ter
o
u
t
to
m
ake
the
re
m
o
v
a
l
of
the
v
ac
uum
fi
l
ter
easier.
-
Tu
rn
the
v
ac
uum
fi
l
ter
co
u
nter
c
l
ock
w
ise
a
¼
t
u
rn
to
re
m
o
v
e
it
fro
m
its
ho
u
sing.
R
e
p
eat
this
p
roced
u
re
for
e
v
er
y v
ac
uum
fi
l
ter
that
is
affected.
-
R
e
pl
ace
the
v
ac
uum
fi
l
ter(s)
and
reasse
mbl
e
the
fi
l
tering
s
y
ste
m
in
the
re
v
erse
order
u
sed
to
co
mpl
ete
the
disasse
mbly
.
W
INTERIN
G
I
n
order
to
w
arn
against
an
y
risk
of
freezing
,
it
is
i
mp
ortant
to
drain
the
fi
l
ter.
1
- T
o
u
nscre
w
drain
plu
g
of
the
l
o
w
er
p
art
of
the
tank
and
to
re
m
o
v
e
the
v
a
lv
e
,
in
order
to
air
the
fi
l
ter
for
this
w
intering
p
eriod.
C
AU
TI
O
N
:
T
O
D
R
A
IN THE FI
L
TER
W
ITH
OU
T CRE
A
TIN
G
INC
OM
IN
G
A
IR
O
N THE HI
G
HER P
A
RT
W
HICH C
A
N PER
MA
NENT
L
Y
DAMAG
E THE T
A
N
K.
2
- T
o
pl
ace
the
l
e
v
er
of
the
v
a
lv
e
I
n
the
„
W
INTER „ p
osition
in
order
to
e
v
ac
u
ate
w
ater
and
to
l
ea
v
e
the
v
a
lv
e
in
this
p
osition.
3
- T
o
drain
the
pump
according
to
the
instr
u
ctions
of
the
m
an
u
fact
u
rer.
MAINTENANCE
CA
U
TION!
Be
f
ore
be
g
i
nn
i
ng
wi
t
h
m
a
i
nt
e
nan
ce
or
s
er
v
ice
work
, al
w
ays
m
a
ke
su
re
t
he
supply
o
f
e
l
ec
t
ric
al p
ower
t
o
t
he
syst
em
h
as
bee
n
re
l
i
a
b
ly d
i
s
co
nn
ec
t
e
d.
1.
Wi
nt
eri
s
i
ng
A
soon
as
the
s
w
i
mm
ing
season
is
o
v
er
,
the
p
rod
u
ct
mu
st
b
e
stored
in
a
dr
y l
ocation
w
here
it
w
i
ll b
e
p
rotected
fro
m
the
w
eather.
(1)
P
erfor
m
the
fina
l
rinse
to
c
l
ean
the
si
l
ica
sand.
(2)
T
o
drain
the
s
y
ste
m
of
w
ater
,
re
m
o
v
e
the
flexi
bl
e
l
ines
and
set
the
v
a
lv
e
l
e
v
er
in
the
“
W
INTER” p
osition.
Lea
v
e
it
in
this
p
osition.
(3)
Drain
the
v
esse
l
no
w u
sing
the
drain
fitting
l
ocated
at
the
b
otto
m
section
of
the
tank.
As
soon
as
the
w
ater
has
b
een
co
mpl
ete
ly
drained
fro
m
the
p
rod
u
ct
,
caref
ully
re
m
o
v
e
a
ll
qu
artz
sand
resid
u
es.
R
einsta
ll
the
drain
fitting
to
p
rotect
the
threads
fro
m
da
m
age.
(4)
B
l
eed
the
pump,
fo
ll
o
w
ing
the
m
an
u
fact
u
rer
’
s
instr
u
ctions
caref
ully
.
(5)
Before
pu
tting
the
p
rod
u
ct
b
ack
into
o
p
eration
in
the
next
season
,
it
is
i
mp
erati
v
e
that
y
o
u m
ake
s
u
re
the
fi
l
ter
is
p
ro
p
er
ly
fi
ll
ed
,
i.e.
ens
u
re
there
is
no
air
inside
it.
2
.
P
u
m
p
m
a
i
nt
e
nan
ce
S
w
i
mm
ing
p
oo
l pump
s
are
designed
to
o
p
erate
w
ith
v
er
y l
itt
l
e
m
aintenance.
H
o
w
e
v
er
,
d
u
e
to
the
reg
ul
ar
,
contin
u
o
u
s
u
se
of
the
p
rod
u
cts
,
the
w
ear
and
exha
u
stion
of
the
indi
v
id
u
a
l
co
mp
onents
is
ine
v
ita
bl
e.
C
ontact
y
o
u
r
l
oca
l
dea
l
er
or
the
m
an
u
fact
u
rer
for
an
y m
aintenance
or
ser
v
ice
w
ork
that
has
to
b
e
p
erfor
m
ed
on
the
pump
s.
On
ly qu
a
l
ified
e
l
ectricians
sha
ll
p
erfor
m
e
l
ectrica
l m
aintenance
or
re
p
air
w
ork.
S
OL
U
TION
S
TO O
P
ERATIONAL
P
RO
B
LEM
S
T
his
p
rod
u
ct
and
its
instr
u
ctions
are
designed
p
ri
m
ari
ly
for
the
u
se
of
p
ri
v
ate
p
ersons
– w
itho
u
t
the
assistance
of
p
rofessiona
l p
ersonne
l,
exce
p
t
in
iso
l
ated
cases.
I
n
the
fo
ll
o
w
ing
, y
o
u
w
i
ll
find
p
ro
bl
e
m
s
and
their
p
otentia
l
ca
u
ses.
T
he
p
ro
bl
e
m
s
sho
w
n
are
co
mm
on
to
a
ll
fi
l
tration
s
y
ste
m
s
and
m
a
y
t
yp
ica
lly
occ
u
r
in
the
co
u
rse
of
u
se
thro
u
gho
u
t
the
y
ears.
Y
o
u
don
’
t
ha
v
e
to
b
e
a
p
rofessiona
l
to
i
mpl
e
m
ent
the
so
lu
tions.
I
f
y
o
u
ha
v
e
qu
estions
a
b
o
u
t
the
w
arrant
y
or
c
u
sto
m
er
ser
v
ice
, pl
ease
cons
ul
t
y
o
u
r
dea
l
er.
P
RO
B
LEM
CA
US
E
S
OL
U
TION
Leakage
of
w
ater
P
oor
connection
of
flexi
bl
e
l
ines
and
in
pu
ts.
C
heck
the
connections
and
p
osition
and
if
necessar
y,
a
pply T
eflon
ta
p
e
and
tighten
the
c
l
a
mp
s.
After
starting
the
fi
l
ter
,
no
w
ater
flo
w
s
o
u
t
of
the
ret
u
rn
o
u
t
l
et.
T
he
v
a
lv
e
is
in
the
FI
L
TER p
osition.
Sh
u
t
off
the
p
rod
u
ct
and
pu
t
the
v
a
lv
e
in
the
right
p
osition.
T
he
p
rod
u
ct
is
l
ocated
at
a
higher
l
e
v
e
l
that
the
p
oo
l’
s
w
ater
l
e
v
e
l
and
for
this
reason
has
e
mp
tied
itse
l
f.
Pl
ace
the
fi
l
ter
in
a
s
u
ita
bl
e
l
ocation
and
fi
ll
it.
T
he
v
ac
uum
co
v
er
or
plu
g
is
bl
ocking
the
ski
mm
er.
R
e
m
o
v
e
the
v
ac
uum
co
v
er
or
plu
g
fro
m
the
ski
mm
er.
7
The filtering ti
m
e
mu
st
b
e ada
p
ted to the cli
m
atic conditions and the fre
qu
enc
y
of
u
se of the s
w
i
mm
ing
p
ool. D
u
ring seasons in
w
hich the
p
ool is
u
sed
,
it is i
mp
erati
v
e that the filter s
y
ste
m
is
pu
t into o
p
eration e
v
er
y
da
y
for a s
uffi
cient
p
eriod of ti
m
e
,
to ens
u
re at least one co
mp
lete transfer/cleaning of the
w
ater
v
ol
um
e.
(2)
R
eg
u
larl
y
check the
w
ater le
v
el of the
p
ool and the o
p
erating
p
ress
u
re of the filter s
y
ste
m
.
(3)
C
lean the ski
mm
er and
pump
p
re
-
filter
b
askets reg
u
larl
y
.
(4) Be s
u
re to re
p
lace
y
o
u
r filter sand a
pp
roxi
m
atel
y
e
v
er
y
t
w
o
y
ears.
(5)
R
e
m
o
v
al of the riser
p
i
p
e
w
ith
w
ater distri
bu
tor (1 co
mp
onent). It
m
a
y
b
e the case that the
w
ater distri
bu
tor is da
m
aged
,
either
w
hen the filter is installed or d
u
ring later
u
se. The
m
ain
v
isi
b
le effect is the introd
u
ction of the sand into the
p
ool thro
u
gh the
pump
ing f
u
nction. The da
m
aged co
mp
onent
mu
st
b
e re
p
laced in this case.
For this
,
y
o
u
mu
st
p
roceed as follo
w
s:
-
R
e
m
o
v
e the riser
p
i
p
e
w
ith
w
ater distri
bu
tor.
-
Briefl
y
rinse o
u
t the filter to
m
ake re
m
o
v
al easier.
-
R
e
p
lace the riser
p
i
p
e
w
ith
w
ater distri
bu
tor and reasse
mb
le the filter s
y
ste
m
in re
v
erse order
Manual Pool Filter 300 6-sprachig 2021_2 neu.indd 7
Manual Pool Filter 300 6-sprachig 2021_2 neu.indd 7
28.05.21 14:36
28.05.21 14:36