Pool Filter 300 - Pool Filter Set 300-2,5 m3/h
1
3
a - HY
D
RA
U
LIC CONNECTION
S
1
- T
o
scre
w
the
threaded
connection
on
„ P
UM
P „
o
u
t
l
et
of
the
mul
tichanne
l v
a
lv
e
, w
hi
l
e
ha
v
ing
b
eforehand
co
v
ered
the
threading
w
ith
a
score
of
T
eflon
t
u
rns.
T
his
connection
can
b
e
fixed
to
the
P
UM
P-
VALV
E
connection
p
i
p
e.
I
n
this
case
,
it
is
necessar
y
to
se
p
arate
it
fro
m
the
p
i
p
e.
2
- T
o
add
the
connection
p
i
p
e
on
the
end
p
re
v
io
u
s
ly p
ositioned
and
scre
w
it
to
connection.
3
- T
o
scre
w
to
other
„ RET
U
RN „
and
„
WAS
TE „
o
u
t
l
ets
the
threaded
connections
w
hi
l
e
not
forgetting
to
p
osition
the
O
ring
on
the
scre
w
thread.
”RETURN” - Outlet to discharge tubes
”PUMP” - Inlet filter, corresponding to discharge of the pump
”WASTE” - Waster outlet
4
- T
o
then
connect
the
other
end
of
the
connection
p
i
p
e
to
the
pump
.
N
ot
to
generate
too
mu
ch
constraint
in
the
connection
p
i
p
e
,
it
can
b
e
necessar
y
to
m
ake
the
mul
tichanne
l v
a
lv
e
s
w
i
v
e
l
aro
u
nd
its
v
ertica
l
axis.
5
- T
o
fina
lly
tighten
the
scre
w
s
of
the
p
i
p
e
c
l
a
mp
.
T
he
v
a
lv
e
is
no
w
interde
p
endent
of
the
tank
and
sea
l
ing
is
ass
u
red.
6
- T
o
connect
the
pump
s
u
ction
(horizonta
lly
on
the
pump
)
to
the
ski
mm
er
and
the
„ RET
U
RN „
o
u
t
l
et
v
a
lv
e
to
the
discharge
t
ub
e.
According
to
m
ode
l
of
s
w
i
mm
ing
p
oo
l,
to
do
so
u
se
either
a
groo
v
ed
nozz
l
e
and
flexi
bl
e
t
ub
es
w
ith
a
38
mm
dia
m
eter
,
or
nozz
l
es
to
stick
and
the
p
i
p
e
of
50
mm
in
dia
m
eter.
I
n
the
case
of
the
flexi
bl
e
t
ub
es
,
to
ens
u
re
the
sea
l
ing
w
ith
c
l
a
mp
s.
T
o
en
v
isage
a
drainage
p
i
p
e
(not
p
ro
v
ided)
on
the
„
WAS
TE „
o
u
t
l
et
for
w
aste
w
ater.
I
t
is
p
ossi
bl
e
to
a
l
so
en
v
isage
on
insta
ll
ation
a
sto
p v
a
lv
e
to
the
ski
mm
er
and
another
on
the
re
v
ersa
l
of
the
s
w
i
mm
ing
p
oo
l
flo
w,
in
order
to
b
e
a
bl
e
to
ins
ul
ate
the
fi
l
tration
pl
ate
of
the
p
oo
l
(in
p
artic
ul
ar
for
the
c
l
eaning
of
the
pump b
asket
and
w
intering)..
AJUSTMENT OF PRESSURE GAUGE:
II
t
is
ad
v
isa
bl
e
to
reg
ul
ar
ly l
ook
at
the
p
ress
u
re
stated
on
the
p
ress
u
re
ga
u
ge.
I
t
indicates
the
l
e
v
e
l
of
sat
u
ration
of
fi
l
ter.
T
he
m
ore
the
fi
l
ter
is
c
l
ogged
,
the
greater
the
p
ress
u
re.
T
he
p
ress
u
re
ga
u
ge
is
p
ro
v
ided
w
ith
a
re
m
o
v
a
bl
e
arro
w m
aking
it
p
ossi
bl
e
to
indicate
the
p
ress
u
re
rating.
Be
y
ond
0
,
5
b
ar
of
o
v
er
p
ress
u
re
,
to
carr
y
o
u
t
w
ashing
of
fi
l
ter.
3b
-
S
TART
UP
T
he
first
o
p
eration
consists
in
re
m
o
v
ing
a
ll
the
d
u
st
contained
in
the
sand.
1
- T
o
pl
ace
the
v
a
lv
e
in
„
WAS
HIN
G
„ p
osition.
2
- T
o
acti
v
ate
the
pump
for
a
fe
w m
in
u
tes
u
nti
l
the
mu
dd
y
ing
indicator
is
c
l
ean.
(to
m
ake
s
u
re
that
w
ater
circ
ul
ates
nor
m
a
lly
and
that
the
pump
has
correct
ly
started).
3
- T
o
sto
p
the
pump
.
4
- T
o
pl
ace
the
v
a
lv
e
in
the
„ RIN
S
IN
G
„ p
osition
5
- T
o
acti
v
ate
the
pump
for
20
seconds
a
pp
roxi
m
ate
ly
.
6
- T
o
sto
p
the
pump
.
T
he
fi
l
tration
gro
up
is
read
y
to
f
u
nction.
4-O
P
ERATION
IMPORTANT: NEVER ACTIVATE THE VALVE WHILE THE PUMP IS OPERATING.
NEVER REMOVE PARTS IF THE FILTER IS PRESSURISED.
O
RIFICE
P
UM
P
!
5
1.
FI
L
TR
A
TI
O
N
-
Set
the
v
a
lv
e
at
“FI
L
TR
A
TI
O
N”
.
-
Start
the
pump
.
Water
w
i
ll b
e
fi
l
tered
thro
u
gh
the
sand.
NOTE
:
N
ote
and
record
the
p
ress
u
re
reading
sho
w
n
on
the
p
ress
u
re
ga
u
ge
the
first
ti
m
e
the
s
y
ste
m
is
in
o
p
eration.
T
his
reading
w
i
ll b
e
y
o
u
r
f
u
t
u
re
reference
p
ress
u
re
“P
1
”
for
reg
ul
ar
o
p
eration.
2.
RIN
S
IN
G
THE FI
L
TER
I
f
the
o
p
erating
p
ress
u
re
exceeds
the
reference
p
ress
u
re
“P
1
” by m
ore
than
0.5
b
ar
,
the
sand
mu
st
b
e
rinsed.
(1)
Sto
p
the
pump
.
(2)
Set
the
v
a
lv
e
to
“RIN
S
E”
.
(3)
Start
the
pump
and
l
et
it
r
u
n
u
nti
l
the
c
l
o
u
diness
stat
u
s
indicator
signa
l
s
that
the
necessar
y
c
l
ean
l
iness
has
b
een
achie
v
ed.
(4)
Sto
p
the
pump
.
(5)
Set
the
v
a
lv
e
at
“F
LUS
H”
.
(
Flu
shes
the
l
ines
and
discharges
into
the
se
w
er
s
y
ste
m
.)
6)
T
o
acti
v
ate
the
pump
d
u
ring
20
seconds.
Sto
p
the
pump
and
ret
u
rn
to
„ FI
L
TR
A
TI
O
N „ m
ode.
(
7
)
Start
the
pump,
the
P
o
p
erating
p
ress
u
re
mu
st
fro
m
no
w
get
c
l
oser
to
P
0
R
ecomme
nda
tio
ns
f
or
fi
ltr
a
tio
n
:
1) It is essential to check that the s
u
ction o
p
enings are not o
b
str
u
cted;
2) It is ad
v
isa
b
le to sto
p
the filtration d
u
ring
m
aintenance o
p
erations on the filtration s
y
ste
m
;
3)
R
eg
u
larl
y
m
onitor the filter clogging le
v
el;
5
IMPORTANT: NEVER ACTIVATE THE VALVE WHILE THE PUMP IS OPERATING.
NEVER REMOVE PARTS IF THE FILTER IS PRESSURISED.
CHECK THE UNCLOSING SUCTION NOZZLE.
Manual Pool Filter 300 6-sprachig 2021_2 neu.indd 5
Manual Pool Filter 300 6-sprachig 2021_2 neu.indd 5
28.05.21 14:36
28.05.21 14:36