![background image](http://html1.mh-extra.com/html/u-prox/ip400/ip400_installation-and-programming-manual_3079604014.webp)
14
or for both access points (A + B).
As long as access point is in "Free Pass" mode, the lock is held in open position, the
panel stores a log event "Access granted" on presentation of RF ID code regardless
of the antipassback state of, schedules, etc. It is used to control the presence of
personnel on the premises in case of an emergency.
To ensure "Free Pass" mode when using locking devices with mechanical re-
platoon you must control access point state. Locking devices with mechanical re-
platoon can be unlocked with current pulse and remain unlocked until access point is
not opened. While closing door, locking device goes into a closed state. Panel in
"Free Pass" mode tests the door contact. Each closing of door again gives unlocking
signal to the door.
“Blocking" mode
If it is necessary to deny access to AP to all users of the system, the panel switches
into “Blocking" mode. If AP is in “Blocking" mode, the passage is granted only to
owners of RF IDs with the sign "Security Service". AP cannot be opened by pressing
RTE.
In Mode "Blocking" LED is alternately flash red and yellow
Access point goe
s into “Blocking" mode after the operator command from the
computer or after loop violation designated as BLOCKING. Access point is in
“Blocking" mode for as long as the loop is violated or until the command from the
computer (while the loop is broken, command from the computer will not work).
Panel allows to configure loop function
“Blocking" for access point A, B, or for both
access points (A + B).
RF ID properties (cards)
Code (RF ID card code)
Each card has a unique code which is set at the time of its manufacture. It consists
of 10 hexadecimal digits.
PIN-code
Additional code is assigned to the card. It consists of no more than six decimal digits.
It can be used together with readers that have a built-in keyboard.
Enter PIN code with the reader's keypad and press '#' key. Always enter PIN code
AFTER the card pass. If PIN-code is correct, panel unlocks access point and grants
access. Otherwise, panel generates a warning signal, and records "Invalid PIN-
code" event into the log. Door remains closed.
Validity (of Card)
Card Validity expiration date
Alarm Cancel
Passing the card to door reader, when the door is in "Alarm" state, panel registers
event "Alarm cancelled" and puts the door to Normal mode. If the card that has no
right to cancel the “Alarm” is passed, the door will remain in the same state. “Access
denied. Alarm Status" event recorded into the log.
Security Service
Security Service mark gives the right of access to a blocked door.