http://u-prox.com 

18

 

 

Return  panel  to  the  factory  settings  to  eliminate  the  panel 
association to the system 

e. 

In  the  case  of  access  control  system  server  IP  address  change 
panel will initiate the automatic configuration routine, but the data 
exchange will be possible with previously connected system only.  

 

Global antipassback 

U-Prox  IP400  control  panel  can  operate  in  a  system  of  global  antipassback.  The 
main controller U-Prox IC A tracks the location of a person on the fact of its passage 
through  the  access  point.  U-Prox  IC  A  receives  data  about  the  passages  from 
control panels NDC F18 IP, U-Prox IP100, U-Prox IP300, U-Prox IP400. 

The  basis  of  the  global  antipassback  is  the  zoned  antipassback.  The  facility  is 
divided  into  rooms  -  zones  of  access  or  areas.  With  this  division  the  entrance  to 
another area is exit from the previous one, and the passage in the area is possible 
through various access points. 

Antipassback control panel receives data from the access control panels and tracks 
the movement of personnel from area to  area . Also can  be tracked the location of 
the person who has multiple IDs (See Figure 6). 

 

Fig. 6. Allocation of access areas

 

Initially an employee has the location "unspecified". After the first presentation ID to 
a reader's location  

The location "unspecified" is assigned when registering a new employee, or after the 
system operator command "location reset" of person is fixed by U-Prox IC A. 

Summary of Contents for IP400

Page 1: ...1 001 Access control panel U Prox IP400 Installation and programming manual...

Page 2: ...tment of external devices and panel configuration are described in Working with the device section Technical support To get warranty and technical support you can apply to authorized service centers s...

Page 3: ...output 15 The communicator 15 Global antipassback 18 How to work with the device 20 Connection procedure 21 Installation recommendations 21 Connecting external readers 22 Connecting LoopControl 23 Re...

Page 4: ...nt of non volatile memory U Prox IP400 is an access control system that provides for access control in variable establishments in small offices as well as on large enterprises with number of employees...

Page 5: ...cts NO COM 1 A 24 V One USB port for network settings configuring for connection to ACS server Ethernet port 10BASE T 100BASE TX Adjusted with U Prox IP software Real time clock Antipassback Non volat...

Page 6: ...ts one for entrance and the other one for exit door of this type is called double sided door A door with a reader on one side has only one Access point Entry point and it is called single sided door D...

Page 7: ...appearance for this purpose System detects the global antipassback violation when somebody tries to re enter such area without exit or tries to enter somewhere from the area he have not enter System g...

Page 8: ...panel is to be downloaded after all parameters are set modes of inputs outputs access rights and others During downloading parameters are rewritten into access control panel Description and operation...

Page 9: ...http u prox com 9 Location of jumpers and removable pads with connectors on access control panel board and their function is shown in Fig 2 Fig 2 U Prox IP400 components...

Page 10: ...lly disclosed 1 General NC2 normally closed Relay contacts 2 NO2 normally disclosed 2 General NO3 normally disclosed Relay contacts 3 3 Total NO4 normally disclosed Relay contacts 4 4 General 1BZ Buzz...

Page 11: ...he network settings Jumpers Service TMP tamper contact FACT Factory reset Buttons But1 access point A RTE button But2 access point B RTE button Sound and light panel Yellow LED Standby mode periodic b...

Page 12: ...ee pass has the highest priority as this mode is activated in the event of a fire followed by modes of Blocking Alarm and Normal in decreasing order of priority Normal mode This is the main mode of pa...

Page 13: ...eeded and in case of RF ID matching attempt In Alarm mode panel activates outputs programmed as ALARM and SIREN Alarm output remains activated till Alarm mode is turned off For output SIREN siren time...

Page 14: ...mputer or after loop violation designated as BLOCKING Access point is in Blocking mode for as long as the loop is violated or until the command from the computer while the loop is broken command from...

Page 15: ...y order for several functions Blocking Siren Alarm Programmable output In addition there is programmable operation mode for each output start stop output remains active until the corresponding command...

Page 16: ...events Waiting for server commands Algorithm of working on the Internet local wire net 1 If DHCP on IP is 0 0 0 0 obtaining of IP address within local network affiliate at panel launch 2 Update of sta...

Page 17: ...ends data packages announcing access control system server about itself as a new device in the local network Despite it is broadcast announcement it is limited with single range local network and acti...

Page 18: ...U Prox IP300 U Prox IP400 The basis of the global antipassback is the zoned antipassback The facility is divided into rooms zones of access or areas With this division the entrance to another area is...

Page 19: ...n etc See Figure 7 Fig 7 Tracking the violations In case of lost communication with the access control panels forced entry free pass etc U Prox IC A merges access areas together considering that the p...

Page 20: ...he U Prox IP software must be enabled antipassback mode General for the door For each access control dialog box must be specified master antipassback control panel and reaction to the deprivation of c...

Page 21: ...h the loops in accordance with the sections below 11 Perform installation of the Ethernet cable into the connector terminal blocks 12 Place the top cover and fix it with screw 13 Connect the panel to...

Page 22: ...Blue inclusion of buzzer signal Brown inclusion of red indicator Orange inclusion of green indicator Black GND Red 12 V Current consumption of each external reader connected to terminals 12 V should...

Page 23: ...closing and opening Normal state of the loop from 1 4 kOm to 3kOm Line shortage less than 1 4 kOm the broken line more than 3 kOm It is recommended to use supplied resistors Request to Exit button RT...

Page 24: ...Z4 terminals is on the Fig 13 Fig 13 Connecting door contacts Z3 and Z4 inputs function assigned as follows Z3 door contact of access direction A Z4 door contact of access direction B Program input as...

Page 25: ...tact and RTE button of access direction B Any of 8 inputs can be assigned as a combined for service of door contact and RTE button Integration with the fire alarm system It is necessary to program the...

Page 26: ...t of security control panel can be directly connected to this input When security alarm is on loop of access control panel designated as Blocking is broken All access points supervised by an access co...

Page 27: ...o not allow long power supply For these latches program the lock time as short as possible to prevent coil overheating Assign relay outputs as outputs of locks at panel programming for proper operatio...

Page 28: ...on data transmission to ACS server is initiated Panel provides protection against arbitrary interference due to the encryption of data with 256 bit key and against panel substitution supervising the u...

Page 29: ...do not set if you use DHCP o IP address o Subnet Mask o IP address of the gateway router Internet 1 not necessarily in the local area network o IP address of the gateway router to the Internet 2 opti...

Page 30: ...uring access points one way or two way access point Antipassback mode time of entering PIN code or off b Setting access direction of reader time of doors opening signs of Alarm Prohibited Door forced...

Page 31: ...SB and configure the device using the software Configurator Replacing the device firmware 1 De power the panel 2 Remove the top cover of panel 3 Connect the notebook with USB cable to the panel 4 Usin...

Reviews: