18
Return panel to the factory settings to eliminate the panel
association to the system
e.
In the case of access control system server IP address change
panel will initiate the automatic configuration routine, but the data
exchange will be possible with previously connected system only.
Global antipassback
U-Prox IP400 control panel can operate in a system of global antipassback. The
main controller U-Prox IC A tracks the location of a person on the fact of its passage
through the access point. U-Prox IC A receives data about the passages from
control panels NDC F18 IP, U-Prox IP100, U-Prox IP300, U-Prox IP400.
The basis of the global antipassback is the zoned antipassback. The facility is
divided into rooms - zones of access or areas. With this division the entrance to
another area is exit from the previous one, and the passage in the area is possible
through various access points.
Antipassback control panel receives data from the access control panels and tracks
the movement of personnel from area to area . Also can be tracked the location of
the person who has multiple IDs (See Figure 6).
Fig. 6. Allocation of access areas
Initially an employee has the location "unspecified". After the first presentation ID to
a reader's location
The location "unspecified" is assigned when registering a new employee, or after the
system operator command "location reset" of person is fixed by U-Prox IC A.