12
o
frequent blinking - waiting in uploading mode (jumper TMP off), this
indication means that the attempt to upgrade the firmware failed
o
6 short blinks - successful
upgrade of firmware
o
2 short blinks - uploading mode exit
6 short beeps (enclosure opened and shorted jumper FACT) - Factory
reset (reset to factory settings was done)
LED
Link
:
On - Ethernet cable is OK
LED
Akt.
:
Frequent blinking - Data Exchange.
Panel operation
The panels supplied unloaded with factory settings below in document. In this state,
the indicators of readers and the yellow LED on the panel flashes once per second.
To make the panel work in access control system (ACS) you have to upload a
network setting using the "Configurator" software and USB port.
If no inputs are triggered panel goes to mode “Normal” after uploading the
configuration. Panel can supervise two independent access directions. There are
four different modes of access point: "Normal", "Alarm", "Blocking" and "Free pass".
Mode "Free pass" has the highest priority, as this mode is activated in the event of a
fire, followed by modes of "Blocking", "Alarm" and "Normal." in decreasing order of
priority.
"Normal" mode
This is the main mode of panel. In this mode the panel grants or denies access to
RF ID owners. In “Normal" mode the readers blink red.
Passing after entering RF ID
To pass through user enters contactless RF ID to the reader. If RF ID is registered
and the passage is granted, access point opens (the panel activates the actuator).
The reader LED becomes green.
Passing after entering RF ID and PIN code
On entering enrolled RF ID, panel tests whether PIN code is required, and, if
required, waits for entering PIN code. After entering the correct PIN code, AP opens
(the actuator is activated).
The reader LED becomes green.
Passing upon Request to Exit (remote opening of doors)
Exit from premises with single-sided door or passing of users is granted upon
pressing Request to Exit (RTE). Pressing and releasing of RTE AP opens the door
(actuator is activated). The reader LED becomes green.
Access denial upon entering RF ID
Access may be denied to RF ID owner due to the following reasons (the reader LED
is red)::