21
Connection procedure
1.
Before installation, do initial setup of panel (that specifies settings of network
parameters) with utility "Configurator" via USB port
2.
In the place of installation of the panel do preparing - mark and drill the holes
(see Installing panel)
3.
Run the cable lead from the power supply
4.
Run the cable lead from the actuator (lock)
5.
Install external readers and run their cables (if necessary)
6.
Run loops from sensors / buttons
7.
Run cable lead-Ethernet (if necessary)
8.
Placing of installation cables in the wall
9.
Fit and fix access control panel enclosure
10. Run the wire commutation of power supply, lock, reader, inputs of the panel
with the loops in accordance with the sections below
11. Perform installation of the Ethernet cable into the connector terminal blocks
12. Place the top cover and fix it with screw
13. Connect the panel to ACS (in accordance with the instructions ACS)
14. By means of ACS, perform full panel adjustment (set of inputs, outputs,
schedules, RF IDs, etc.).
15. Ready for operating
Installation recommendations
Access control panel should be
placed in a place accessible for
maintenance.
To install the access control panel
on the wall (see Fig. 10), do the
following:
open the cover, attach
the enclosure to proposed
site of attachment and
make layout of holes;
pass the wires through
the holes in the wall of
enclosure;
attach the access control
panel;
connect the wires
Fig. 10. Marking fixing holes
When the panel is in stand-alone mode, paragraphs 11 and 12 should be
performed before paragraph 2.