28
Connection
Wired computer network used for U-Prox IP400 communication to the ACS server.
Device setup is possible with using autoconfiguration or manually with a PC using
the software "Configurator":
Appropriate configuration provides:
Assigning of static or dynamic (DHCP) IP address to a device;
Working with two (primary and backup) IP or DNS (Domain Name Service)
of ACS server addresses;
Working on the Internet (service of remote branches) with the ability of
reserving paths to the Internet via the second router;
Panel works automatically after data upload from the ACS server. It processes
access rights for IDs passed grants or denies access and sent event reports to the
server.
Panel communicator operates in notification mode. If there is event (passage, input
violation) data transmission to ACS server is initiated.
Panel provides protection against arbitrary interference due to the encryption of data
with 256-bit key and against panel substitution supervising the unique serial number
of the device at its work in the network. It also provides supervision of the
communication channel by means of periodic test signals from the device.
Wired computer network (Ethernet)
Ethernet interface is used to connect components of the system (PC and access
control panels) in the network. Ethernet cable length without additional equipment
can be up to 100 meters
Use standard Ethernet cable, and RJ45 connector. Transfer rate is up to 100Mb / s.
In
Fig.
18 examples of connection cable Ethernet are shown.
Ethernet connector 1
Ethernet connector 2
Direct connection (to the switch or router )
1. white-yellow
1. white-yellow
2. yellow
2. yellow
3. white-green
3. white-green
4. blue
4. blue
5. white-blue
5. white-blue
6. green
6. green
7. white-brown
7. white-brown
8. brown
8. brown