21
06
Bus over current
Check the load.
08
Load is too heavy
Check the load.
10
Position check error
Check synchronizer, see 8.2.
11
Encoder error
Check encoder, see 8.4.
13
Machine type error
Check identifier, see 8.6.
14
Trimmer SOL. error
Check SOL. whether direct short.
15
REV SOL. error
Check SOL. whether direct short.
16
Wiper SOL. error
Check SOL. whether direct short.
17
Foot lifter SOL. error
Check SOL. whether direct short.
8. Signal
Checking
Press wheel button during power on, it will display “TEST” and then enter
the mode of Measurement of Input Signal. Turning wheel button can change
the index of signal test.
8.1 Pedal
Display of the different pedal position as below:
Display code
Descriptions
High speed
The second segment forward, pull is 02~99.
Low speed
The first segment forward, pull is 01.
Balance position Default.
Foot position
The first segment backward.
Trimmer position The second segment of backward.
Error position
Speed controller fault or disconnected.
8.2 Synchronizer
Turn the hand wheel by hand equably, display of up position.
8.3 Switch
Display code
Descriptions
L:
The LED lightness, can be set by
and
.
R:
The state of REV. switch.
C:
The state of COR. switch.
S:
The state of safety switch.