16
D01
Up lever
0
~
359
(
°
)
60
Up lever degree.
D02
Down lever
0
~
359
(
°
)
215
Needle bar down degree.
D03
Trimmer act
0
~
359
(
°
)
250
Trimmer act degree.
D04
Trimmer
release
0
~
359
(
°
)
0
Trimmer release degree.
D05
Reverse act
0
~
359
(
°
)
300
Reverse SOL. act degree.
D06
Reverse
release
0
~
359
(
°
)
300
Reverse SOL. act release degree.
D07
Clamp act
0
~
359
(
°
)
180 Clamp
act
degree.
D08
Clamp release
0
~
359
(
°
)
270 Clamp
release
degree.
D09
Puller start
0
~
359
(
°
)
0
Puller starts degree per round.
D10
Puller end
0
~
359
(
°
)
0
Puller stops degree per round.
6.5 Special parameter
SN Name Range
Default
Descriptions
O01
Stitches of slow
sewing at start
0~10
(needle)
3
The stitches of slow sewing at start
when trimming is finished. The
speed of slow sewing is set in
S08
.
O03
Machine type
1~30
22
According to the machine type.
O05
Duty of foot lifter
output
10~99
(%)
50
The duty cycle of PWM for signal of
foot lifter solenoid. The power will
be greater if this value is bigger, at
the same time, the heat is more.
O06
Foot lifter auto
release
ON~OFF
ON
When it is “ON”, the foot lifter
solenoid will be released
automatically after the time desired.