Doc No. FM0713 Issue C Page 33 

 

17. SYSTEM PROGRAMMING

 

 

VERIFY 

Click on this button to check that a previously saved file you have on your computer matches the programming 

on a door panel. “Open” the file then click on “Verify” - you will receive confirmation via the “Information” 

window if the files do/do not match.  

 

SHOW NUMBER OF FLAT ENTRIES 

Click on this button to check if you have inadvertently duplicated flat numbers. Any duplications and which 

distribution nodes they are on will be shown on the screen.  

 

CLEAR ALL FLAT DATA 

Click on this button to clear all information from the screen only, not the door panel. Once you have entered 

the new flat numbering data click on the 

Send ALL Data TO Panel

 button to over-write all previous door 

panel programming. 

 

PORT 1 TO PORT 8 

This is where you enter the flat numbers that are connected to the distribution node output Ports.  

For example; if flat 10 is connected to Port 1 of Board 1 then type “10” in the Distribution Node 1 Port 1 box.  

If Flat 11 is connected to Port 2 of Node 1 then type “11” in Port 2 box.  

 

LOCATION 

This is a text box where you can add a note of where the distribution node is located in the building e.g. first 

floor riser cupboard.

 

 

NEXT NODE 

Click on this button when the flat numbers have all been entered for the first distribution node.  

The DIL switch graphic will change to show how the actual DIL switches on distribution board 2 will need to be 

set. Continue filling in the flat numbers against the relevant Port numbers then click on the “Next Unit” button 

again to move on.  

 

PREVIOUS NODE 

Click on this button to go back to the previous distribution node.  

Note: you can also slide the DIL switch graphic to directly select any distribution node. 

 

AUTO FILL 

If the flat numbers run sequentially and there are no distribution node ports left un-connected then the Auto 

Fill option will greatly speed up programming.  

 

Enter the first flat number (lowest in sequence) in the “Start” box and the highest number in the “End” box.  

Enter a “1” in the “Increment” box if the numbering is sequential 

Enter a “2” if you have odd or even numbers only, or enter whatever number increment is.  

Enter “FFFF” in the Port number box you want the sequence to start.  

Now click on the “Auto Fill” button and the flat numbering will be entered for you.  

Use the Next/Previous Node buttons to manually check the numbering is what you require. 

 

SEARCH 

If you want to quickly find where a particular flat is connected on the system; enter the flat number in the box 

and click on the “Search” button. The port number and distribution node number the flat is connected to will 

be displayed, this function will also highlight any duplication of the same flat number. 

 

 

 

 

 

 

 

 

 

 

 

 

Summary of Contents for Entel Ultra

Page 1: ...roduct improvement and reserves the right to modify the specification of its products If any variation to the details in this document are suspected please contact Tynetec s Technical Support on 01670...

Page 2: ...es 7 5 Distribution Nodes 10 6 Door Panels 13 7 Camera Panel 16 8 Telephones 17 9 Video Phones 19 10 BT DECT Telephone Interface 21 11 Video Amplifiers Switchers 22 12 Lock Release 24 13 Door Contacts...

Page 3: ...s this also includes a trade timeclock and a low voltage power supply housed in an IP65 lockable steel enclosure The 8 port distribution nodes are available in IP65 ABS or lockable steel enclosures th...

Page 4: ...sed for the video connection between the node and phone If existing cabling is being utilised then check sufficient cores are available If a PAC reader is fitted in the door panel then an additional 6...

Page 5: ...onnected to both Distribution Nodes Telephones connected to both Distribution Nodes 2 MULTIPLE SPEECH PATHS OPTION 1 DIGITAL On multi entrance systems multiple speech paths can be achieved by fitting...

Page 6: ...Distribution Nodes Ground Floor 3 MULTIPLE SPEECH PATHS OPTION 2 DECK ACCESS To help speed the passage of visitors through large deck access systems the floor level functional panels can be connected...

Page 7: ...p with the door hinged on the left hand side The door can be swapped to hinge from the right or the back plate can be inverted if the cable entry plate is required on the bottom Always ensure propriet...

Page 8: ...y The battery is protected by a 20mm 4A quick blow fuse located on the battery protection board 4 07 SYSTEM POWER REQUIREMENTS To ensure the Entel Ultra System Node PSU has sufficient capacity the tot...

Page 9: ...of 0 5mm cable 10 ohms then the drop would be 5V By using 1 pair of wires the resistance will be halved to 5 ohms therefore the volts drop will be halved to 2 5V Always ensure there is a minimum 10 0...

Page 10: ...rd has an 8 way DIL switch for setting a unique ID Distribution board ID s are set in Binary see table below DIL SWITCH No 1 2 3 4 5 6 7 8 BINARY CODE 1 2 4 8 16 32 64 128 Distribution board ID s shou...

Page 11: ...in to switch on off with increasing speed for several minutes Remember to set the correct Board ID and press RESET again when the cleaning cycle is complete 5 06 TELEPHONE SYSTEMS Up to 8 flats can be...

Page 12: ...nes and ZVT455 video phones This Link may be moved to A if alternative manufacturer s telephones are being used that require a switched 0V for the door open LED 5 11 TELEPHONE DISTRIBUTION BUS WIRING...

Page 13: ...elephone is turned off a not available tone is sounded When the door lock is released a distinct pulsed tone is sounded to indicate the door is open 6 01 DOOR PANEL RANGE 6 02 PAC READER OPTION All do...

Page 14: ...x for cable entry this may allow water to enter and damage the electronic components or keypad Cable entry into the backbox should be through the side or rear 20mm knockouts provided IMPORTANT the bac...

Page 15: ...ti entrance systems set DIL switch 1 ON on one door panel only it doesn t matter which one DIL switch 2 should always be OFF 6 09 VOLUME ADJUSTMENT The door panel loudspeaker and telephone earpiece au...

Page 16: ...be clarified with the Supervising Officer The backbox should be cut into the brick work or door screen and sealed with suitable mastic to prevent water ingress 7 03 SURFACE FLUSH COWLINGS If it is not...

Page 17: ...in one of two modes Timed Privacy privacy mode will turn off automatically after a pre set time default 12 hours On Off Privacy privacy mode will remain on until the user turns it off To turn privacy...

Page 18: ...to 70 seconds default 40 seconds There s an option in programming to extend the conversation time until the end of the lock release period 8 06 TELEPHONE CONNECTIONS Each telephone must be individuall...

Page 19: ...are set via the Jumper pins on the PCB inside the video phone 9 02 RING TONE VOLUME Move the 3 position slide switch on the top left hand side of the video phone to select low medium or high volume r...

Page 20: ...l reference and function is listed in the table below Also see the wiring diagram ZV508I ZV516I sheet 1 9 08 PICTURE ADJUSTMENT Use a blunt instrument such as a ball point pen to press the 3 hidden bu...

Page 21: ...tra Distribution Node Connect the interface unit terminal to the Distribution Node output port terminal Connect the interface unit terminal to the Distribution Node output port terminal Connect the in...

Page 22: ...ransmission distances up to 1000 metres when used with good quality RG59 coaxial cable Both the 2 4 output models have adjustable gain and high frequency lift controls to fine tune the video signal on...

Page 23: ...12V relay board to automatically select the video signal from the door panel in use Video from door 1 camera passes through the normally closed contacts onto the video distribution bus Video from doo...

Page 24: ...her point on the wiring it must be on the lock terminals 0V DC LOCK ONLY LOCK RELAY NC1 NO1 Diode Type 1N4001 or MOV Type GNR07D330K 12 03 LOCK CONNECTION The lock relay common terminal C1 should be l...

Page 25: ...bove ANTI TAILGATE When the door is opened the lock release time will be reset to help prevent unauthorised visitors entering the building during the same lock release period i e Anti Tailgating The d...

Page 26: ...cover to avoid accidental operation 14 02 EXTERNAL FIREMAN S SWITCH There are a variety of different types of Fireman s Switches available from many different suppliers the exact make and model will...

Page 27: ...DOOR PANEL 15 PAC EASIKEY 250 The Entel Ultra door entry system can be interfaced to a PAC Easikey 250 access control system to allow residents to enter the building using an electronic key An Easikey...

Page 28: ...ller and an Entel Ultra door entry system The Easikey 250 should be programmed for a fail secure lock type Refer to the PAC Easikey 250 user and installation guide for full details 15 03 ALTERNATIVE A...

Page 29: ...13 Set every other weekday starting Monday MO WE FR 14 Set every other weekday starting Tuesday TU TH SA 15 Set 3 consecutive days starting Monday MO TU WE 16 Set 3 consecutive days starting Thursday...

Page 30: ...tec GUI Graphical User Interface software This software is supplied on a USB flash memory stick along with the programming lead When installing the software you will need to contact Tynetec s customer...

Page 31: ...now the Comm Port number the software will find the Comm Port being used and enter it into the box IMPORTANT before proceeding your Laptop needs to be connected to the door panel as described in Secti...

Page 32: ...you may want click on the yellow Attached Notes and Printer Functions button and record some useful details about the site This button is at the bottom of the green Configuration Data area of the scr...

Page 33: ...numbers have all been entered for the first distribution node The DIL switch graphic will change to show how the actual DIL switches on distribution board 2 will need to be set Continue filling in th...

Page 34: ...onal door panels Tynetec P No s ZSD501 to ZSD534 DIAL Step Thru Mode for Dial Functional door panels only Tynetec P No ZSD580 If you set DIAL Step Thru Mode then fill each box with flat numbers in the...

Page 35: ...ed 33 34 35 36 37 38 39 40 41 42 43 44 Refer to Figure 2 3x5 Matrix and enter the flat numbers engraved on the buttons in the relevant boxes on the programming screen Enter Flat numbers here Set Stand...

Page 36: ...MMING EXAMPLE 3 EXAMPLE 4 If you have a functional door panel WITH display and you cannot work out which button is which then another option is to temporarily Set Door Panel Type to Digital and click...

Page 37: ...panel display will show HUNG UP LOCK RELEASE TIME This is the time the door lock will remain released from the resident s telephone The LED indicator on ALL telephones will flash green during the lock...

Page 38: ...annels 1 to 8 on the 8 channel video switcher set with ID 1 These outputs can be used to select the correct entrance panel camera for the door panel in use Door panels with ID s 9 to 16 will activate...

Page 39: ...roduces a delay of 10 seconds before the same panel can be used make another call The door panel will display HOLD during this 10 second count down period visitors waiting at other entrances have the...

Page 40: ...th the programming details for the door panel Remember on multi entrance systems you may have more than one File per site if the door panels are programmed differently PRINT COMMISSIONING SHEETS Click...

Page 41: ...Press the door panel button to call the first flat number Check the flat number displayed is the same as that engraved on the door panel button The telephone in the flat should ring and the display s...

Page 42: ...turn the timeclock to AUTO mode If an access code is programmed press the door panel CALL button and the display will show CODE Enter the access code then press the CALL button followed by the 1 butto...

Page 43: ...n the flat you are calling has been left off the hook TRAN the flat you are calling has their call diverted i e your call is being transferred FLAT LOC BUTTON FAULT the telephone has the lock button s...

Page 44: ...Page 44 Tynetec a business unit of Legrand Electric Ltd Unit 10 Cowley Road Blyth Riverside Business Park Blyth Northumberland NE24 5TF Tel 01670 352 371 Fax 01670 362 807 Email sales tynetec co uk W...

Reviews: