Fill up the Warranty Registration Card and
mail it to the indicated address.
GAS SAFETY REQUIREMENTS
–
T
WIN
E
AGLES
G
AS
P
OWER BURNER
Each appliance is set and tested at the factory for the type of gas supply to be used. Identify the
type of gas, either natural gas or LP gas and make sure that the marking on the data plate (rating plate)
matches the gas being supplied to the Power Burner. The data plate is located on the panel behind the
control panel of the Power Burner. Remove the drip pan to visually access the nameplate label from
the front of the Power Burner. A second label with model number and serial number is located under
the right side of the control panel.
All gas connections should be made by a qualified technician and in accordance with local
codes and ordinances. The installation must conform with local codes or, in the absence of local
codes, with either the national Fuel Gas Code, ANSI Z223.1/NFPA 54, or CAN/CGA-B149.1, Natural
Gas Installation Code or CAN/CGA-B149.2, Propane Installation Code.
WARNING:
CHECK TO ENSURE THAT THE GAS SUPPLY HOSE DOES NOT COME IN
CONTACT WITH ANY HOT SURFACE OF THE POWER BURNER.
NEVER CONNECT THE POWER BURNER TO AN UNREGULATED GAS
SUPPLY.
GAS SAFETY REQUIREMENTS
–
T
WIN
E
AGLES
G
AS
P
OWER BURNER
(C
ONTINUED
)
L.P. GAS (LIQUIFIED PETROLEUM /PROPANE)
If your Power Burner is factory built for L.P., the regulator supplied is set for 10” water
column and is for use with L.P. gas only. The factory-supplied regulator must be used.
L.P. GAS SAFETY REQUIREMENT
The LP-gas supply cylinder must be constructed and marked in accordance with the
Specifications for LP-gas Cylinders
of the U.S. Department of Transportation (D.O.T.) or the National
Standards of Canada
CAN/CSA-B339, Cylinders, Spheres and Tubes for the Transportation of
Dangerous Goods, and Commission,
as applicable; and
1. Provided with a listed overfilling prevention device.
2. Provided with a cylinder connection device compatible with the connection for outdoor cooking
appliances.
Specifications
Value
Counter Opening Height
11.50”
Counter Opening Width
22.00”
Counter Opening Depth
20.50”
Btu 70,000
NG Orifice Outer Ring
#30
NG Orifice Inner Ring
#41
LP Orifice Outer Ring
#49
LP Orifice Inner Ring
#53