LEAK TEST
1)
Prepare a leak testing solution of sudsy
water by mixing in a spray bottle with
half liquid soap and half water.
2)
Confirm that all control knobs are in the
OFF position.
3)
Turn the main gas valve supply ON.
4)
Apply leak testing solution by spraying
on the pipe joints, fittings, and hose.
5)
A gas leak is detected if;
a)
there is a faint gas smell and/or…
b)
…growing bubbles appear on any of
the connection points and/or hose,
DO NOT attempt to ignite the Power
Burner and IMMEDIATELY turn off
the gas supply valve.
6)
When there is a gas leak, call a qualified
service technician. DO NOT use the
Power Burner until the leak is corrected.
ELECTRICAL REQUIREMENTS
–
T
WIN
E
AGLES
G
AS
P
OWER BURNER
The Twin Eagles Power Burner has a power transformer which is concealed in a stainless steel box with
an attached power supply cord. This transformer must be secured in a dry location.
1.
In an island application locate the Power Burner near the GFCI 120V outlet in a dry location.
2.
Plug-in the transformer’s power cord to the properly grounded GFCI 120V outlet.
AVERTISSEMENT
Instruction pour la mise à la terre electrique:
Cet appareil est muni d’une fiche à trois
broches (mise à la terre) afin de vous protéger
des chocs et doit être branché directement dans
une prise de courant à trois broches
adéquatement mise à la terre. Il ne faut pas
couper ou enlever la broche de mise à la terre
de cette fiche.
WARNING
Electrical Grounding Instructions:
This outdoor gas cooking appliance is equipped
with a three prong (grounding) plug for your
protection against shock hazard and should be
plugged directly into a properly grounded three
prong outlet. Do not cut or remove the third
prong from this plug.
The Power Burner requires 120 volt supply. The power supply cord on the
Power Burner is equipped with a 3-prong (grounded) plug for protection against