7 |
P a g e
CLEARANCE TO COMBUSTIBLE CONSTRUCTION
A minimum clearance of 12” from the sides and 6” from the back of the Power Burner
to adjacent
vertical combustible construction must be maintained.
DÉGAGEMENT DE TOUTE CONSTRUCTION COMBUSTIBLE
Il faut maintenir une distance minimum de 12 po (30.48 cm) sur les côtés et de 6 po (15.24 cm) sur
l’arrière du gril par rapport aux constructions combustibles verticales adjacentes.
CLEARANCE TO NONCOMBUSTIBLE CONSTRUCTION
A minimum clearance of 1” from the back of the Power Burner
above cooking surface to non-
combustible construction is required.
A minimum of 1” clearance to the sides
of the Power Burner above cooking surface to non-
combustible construction is recommended. The Power Burner can be installed directly next to non-
combustible construction below the cooking surface.
DÉGAGEMENT DE TOUTE CONSTRUCTION INCOMBUSTIBLE
Une distance minimum de 1 po (2.54 cm) de l’arrière du Puissant Bruleur au-dessus de toute surface de
cuisson à la construction incombustible est prescrite.
Une distance minimum de 1 po (2.54 cm) des côtés du Puissant Bruleur au-dessus de la surface de
cuisson à la construction incombustible est recommandée. Le Puissant Bruleur peut être installé
directement à proximité d’une construction incombustible en-dessous de la surface de cuisson.
CLEANING & MAINTENANCE
–
T
WIN
E
AGLES
G
AS
P
OWER BURNER
SPIDER AND INSECT WARNING
Spiders and other insects can nest in the burner of this and any other Power Burner, which causes the gas
to flow from the front of the burner. This dangerous “condition” can cause a fire behind the valve panel, damaging
the Power Burner and making the Power Burner unsafe to operate. Inspect the burners once a year or if the Power
Burner has not been used for more than one month or if any of the following conditions occur:
1)
The smell of gas in conjunction with the burner flames appearing yellow.
2)
The Power Burner does not reach temperature.
3)
The Power Burner heats unevenly.
4)
The burner makes popping noises.