background image

 

Coyote Power Burner 

 

CPBLP & CPBNG 

 

For Outdoor Use Only 

 

 

 
IMPORTANT: 

Read the lighting instruction on Page 11 before first time use! 

To installer or person assembling power burner: 

Leave this manual with power burner 

for future reference. 

To consumer: 

Keep this manual for future reference. 

COYOTE OUTDOOR LIVING, INC. 

www.coyoteoutdoor.com

 

Coyote Power Burner 

Use & Care Manual 

For Liquid Propane and Natural Gas Models

 

Conforms to ANSI   
STD Z21.58a-2008 
Certificated to CSA   
STD 1.6a-2008 

4006980

 

 
PUT SERIES NO. LABEL HERE 

Summary of Contents for CPBLP

Page 1: ...embling power burner Leave this manual with power burner for future reference To consumer Keep this manual for future reference COYOTE OUTDOOR LIVING INC www coyoteoutdoor com Coyote Power Burner Use Care Manual For Liquid Propane and Natural Gas Models Conforms to ANSI STD Z21 58a 2008 Certificated to CSA STD 1 6a 2008 4006980 PUT SERIES NO LABEL HERE ...

Page 2: ... maintain for optimum performance and longevity We know you ll enjoy your new power burner and thank you for choosing our product We hope you consider us for future purchases Please read and save the instructions This Manual provides specific operating instructions for your model Use your power burner only as instructed in this manual These instructions are not meant to cover every possible condit...

Page 3: ... of this or any other appliance DANGER DANGER indicates an imminently hazardous situation which if not avoided will result in death or serious injury CAUTION CAUTION indicates a potentially hazardous situation which if not avoided may result in minor or moderate personal injury or property damage WARNING FOR OUTDOOR USE ONLY NEVER operate power burner in enclosed areas as this could lead to gas ac...

Page 4: ... to use or play near the power burner 9 Never attempt to repair or replace any part of the power burner yourself unless specifically recommended in this manual All other services should be performed by a qualified service technician 10 Never lean over an open power burner Do not place clothing or other flammable material on or near the power burner Do not wear loose fitting clothes or long sleeves...

Page 5: ...knobs to the full OFF position Ensure that it can vent leave lid off Do not attempt to use the power burner until the gas has had time to dissipate 24 Do not use power burner until leak check has been made 25 Turn off the cylinder valve when your power burner is not in use 26 Ensure the control knobs are in the OFF position when not in use 27 Use only a Ground Fault Interrupter GFI protected circu...

Page 6: ... other such enclosed areas without an approved ventilation system During heavy use the power burner will produce a lot of smoke Ensure there is adequate area for it to dissipate Ventilation Requirements for Proper Operation of your Power Burner Ventilation for a gas power burner is absolutely mandatory to ensure that your power burner performs as intended and to ensure the safety of you and your f...

Page 7: ...is also required that Two ventilation holes of at least 20 sq inches in size must be present to help release any gas from a leak and allow residual heat to dissipate The counter should be flat and level in reference to the floor LP TANK STORAGE MUST BE ISOLATED IN A SEPARATE COMPARTMENT FROM THAT OF THE POWER BURNER AND IT MUST BE VENTED AS WELL RECOMMEND BOTTOM VENTS FOR LP Cut out Dimensions Fig...

Page 8: ...ed at 11 279 4mm water column W C when equipped with the correct propane orifices on the valves and a propane regulator on the supply line regulated at the residential meter The LP gas power burner is designed to be used with a standard 20 lbs gas cylinder and must be constructed and marked in accordance with specifications of the US Department of Transportation for propane gas cylinders Always ke...

Page 9: ...t is a new or used cylinder to be filled After filling have the gas dealer check for leaks and to see that the relief valve remains free to function Hose and Regulator Comes standard with the power burner The Type 1 connection system has the following features The system will not allow gas to flow until a positive connection has been made NOTE The cylinder control valve must be turned off before a...

Page 10: ...connected to LP tank 3 Completely open LP tank valve by turning cylinder valve knob counterclockwise right to left If you hear a rushing sound turn gas off immediately There is a major leak at the connection Correct before proceeding by calling franchiser for replacement parts 4 Brush soapy solution onto areas where bubbles are shown in LP tank see picture 5 If growing bubbles appear there is a le...

Page 11: ...or call a local fire department for assistance Check the telephone directory under Gas companies for nearest certified LP dealers LP Tank Exchange Exchange your Type 1 cylinder with OPD safety feature equipped ONLY Always keep new and exchanged LP tanks in upright position during use transit or storage Leak test new and exchanged LP tanks BEFORE connecting to power burner Large Capacity Propane Ta...

Page 12: ...mes with a regulator a You need to seal the regulator to the hose using your pipe sealant b Then attach the flare end to your manifold line with no pipe sealant c Next attach your next connection hose not included to the other side of the NG regulator it is also MIP i We suggest using stainless steel corrugated hoses for all NG Power burners ii Make sure that you purchase a hose of adequate length...

Page 13: ... instructions provided in this manual Adjust heat settings to your desired cooking temperature Allow power burner to cool down wipe off any splatters or grease and clean the drip tray as needed Do not put a cover on the power burner while it is still hot as it could start a fire WARNING DO NOT use the power burner if gas odor is present DO NOT stand with head body or arms over the power burner whe...

Page 14: ...e power burner does light after three attempts turn the valves to the Off position and allow the power burner to clear of any built up gas for 5 minutes 5 If at this point the power burner will still not ignite you can try the manual lighting process below with a long stem lighter and you can also contact Coyote Customer Service for further assistance to troubleshoot your power burner 6 To turn th...

Page 15: ...f all dirt and debris from the steel with warm water If you have tough spots to clean then a degreaser such as Formula 409 can be used 2 Next you will want to rinse and dry the steel thoroughly with a clean towel Do not allow the steel to air dry as the standing water can cause surface discoloration 3 The last thing you want to do is to protect to the unit with a good polish There are several poli...

Page 16: ...nd low oxygen corrosion will start to take place 7 Sprays and cleaning solutions containing alkaline lime acid salt might have been left on the grill surface un dried 8 No stainless steel polish was ever used after one of the above mentioned acts took place Ways to Avoid Rust on your Grill 1 Always purchase a Coyote Grill cover for your unit This will ensure that your cover is correct fit and brea...

Page 17: ...CE GUIDELINES 1 Keep outdoor cooking gas appliance area clear and free from combustible materials gasoline and other flammable vapors and liquids 2 Do not obstruct the flow of combustion and ventilation air 3 Keep the ventilation opening s of the cylinder enclosure free and clear from debris 4 Visually check burner flames Burner flames should be blue and stable with no yellow tips excessive noise ...

Page 18: ...ce call Troubleshooting is for general purposes only If the problem still exists contact your dealer or the nearest authorized agency for service Problem Possible Causes and Solutions Power burner will not light when the igniter button is pushed Is your gas supply turned on If this is an L P power burner is there gas in your tank Check your gas level Is one of your burners turned on Allow up to 5 ...

Page 19: ...ylinder valve is open and cylinder has fuel Low heat with the knob on HIGH Check to see if the fuel hose is bent or kinked Make sure the power burner area is clear of dust Check your gas supply and gas pressure If it is only one burner that appears low make sure the orifice or burner is clean Power burner is Too Hot Excess grease build up causing grease fires Damaged or faulty regulator Replace wi...

Page 20: ...or your Coyote Power burner please contact our Warranty Service Center for factory direct assistance Our hours of operation are 8 am to 4 pm CST The phone number is 855 520 1559 and the Fax number is 214 520 1450 You may also fill out warranty claims online at www coyoteoutdoor com Please have your model number serial number and proof of purchase available for any warranty claim Coyote Outdoor may...

Page 21: ...ry or property damage due to improper use or product failure Deterioration or damage due to severe weather conditions such as hail hurricanes earthquakes tsunamis tornadoes terrorism discoloration due to exposure to chemicals either directly or in the atmosphere Acts of God forces of Nature are not covered by this limited warranty ...

Page 22: ...ire Box CPB003 13 Knob Base CPB013 4 Fire Box Holder CPB004 14 Knob CPB014 5 Gas Pipe CPB005 15 Drip Tray CPB015 6 Valve CPB006 16 Leaking Pipe CPB016 7 Fire Tube CPB007 17 Cooking Grid CPB017 8 Back Shield CPB008 18 Hood CPB018 9 Fire Tube Holder I CPB009 19 LP Regulator CCX20034 10 Fire Tube Holder II CPB010 20 NG Regulator CCX20035 CPB LP NG Parts List ...

Reviews: