Appendix A – AFC200 frequency converter parameters table
Parameter /
Name
Function
Available options / measurement
unit / comments
Factory
setting
Change
during
opera-
tion
1.53
F1
F1 frequency
0.0 ... 25.0 %
25,0 %
YES
1.60
Slip comp
.
Slip compensa-
tion
0-NO:
disabled
1-YES:
enabled
0
YES
1.64
Stop mode
Stopping by
coast or accord-
ing to character-
istic
0-Coast:
stopping by running out
after STOP command (voltage taken
off immediately )
1-Ramp:
deceleration to 0 Hz at first,
then shutting down
0
YES
1.65
Direction Lock
Operation direc-
tion lock
0-
Reversal
– bidirectional
1-RIGHT
2-LEFT
0
YES
1.70
Amp. reg. n
Speed regulator
gain
0..5000
60
NO
1.71
Ki of reg.n
Integration time
of speed regu-
lator
0..5000
40
NO
1.72
Amp. reg.T
Torque regulator
gain
0..5000
30
NO
1.73
Ki of reg.T
Integration time
of Torque regu-
lator
0..5000
130
NO
1.74
Amp. reg.S
Motor stream
regulator gain
0..5000
60
NO
1.75
Ki of reg.S
Integration time
of motor stream
regulator
Service parameter
100
NO
1.90
F elim1 min
Minimum fre-
quency of fre-
quency elimina-
tion range num-
ber 1
0.00 ... 320.0 Hz
0.00 Hz
YES
1.91
F elim1 max
Maximum fre-
quency of fre-
quency elimina-
tion range num-
ber 1
0.00 ... 320.0 Hz
0.00 Hz
YES
58
TWERD Power Electronics