17
English
a
WARNING. The washing cycle performed
after the «salt loading» may not work.
1
3
2
4
Fig. 9
Filter unit (Fig. 9):
1) Central filter. - 2) Mesh filter. - 3) Tank bottom filter.
- 4) Salt tank cap.
1
2
Fig. 10a
Spray arms (Fig. 10a):
1) Upper spray arm. - 2) Lower spray arm.
1
2
Fig. 10b
Spray arm rotation identification (Fig. 10b):
1) Spray arm without magnet for identification. 2)
Spray arm equipped with magnet for identification.
5.4.1 Connection to the water drain
The machine is equipped with a built-in drain trap
which must be mandatorily connected to the drain
system of the building.
The correct positioning and sizing of the drain trap are
shown on the installation drawing (See Annex 9.1). The
user must carry out periodic maintenance of the drains
and check that they are not clogged.
If not already connected, connect the grey drain pipe
to the drain connection located at the back of the
machine (3 Fig. 8).
Ö
WARNING. The manufacturer is not liable in
case of environmental pollution due to an
incorrect use of the thermodisinfector.
5.5 Filters, spray arms and regeneration
salt
5.5.1 Filters
Insert the supplied filters in the specific positions.
Constantly check the cleanliness of the filters, especially
the tank bottom filter (3 Fig. 9).
Use this filter to have a high filtering, taking into
account that it will have to be cleaned after each cycle
performed to avoid an excessive build-up of dirt.
Insert the mesh filter (2 Fig. 9) and place it in the tank
seat. Finally, insert the central filter (1 Fig. 9) in the
mesh filter hole.
5.5.2 Spray arms
The two spray arms are supplied loose to avoid possible
breakage during transport. Place the two spray arms
(top and bottom) in their seats and tighten them to the
relative central pin inside the tank as shown in Fig. 10.
- After fixing the spray arms, carry out a test by
manually turning it, making sure that they rotate
freely and without impediments.
Ö
WARNING: For versions with spray arm
rotation control, the spray arm with the
magnet must be positioned below (1 Fig.
10b).
- After machine positioning, make sure nothing is
preventing the tank door from being freely opened.
- Make sure the machine is connected properly to the
electrical supply, to the water supply and to the drain