Page 43 of 77
11.5
Unloading
·
When the cycle ended successfully (including pressing the
START/STOP
key, or any failure, after completing the sterilization
stage) message "Cycle Ended" (and the relevant failure message, if
applicable) is displayed on the screen.
·
Verify than there is no pressure in the chamber, according to the
reading on the display. Only then you may open the door.
Warning
To avoid sever injuries from hot steam when opening the door:
¾
It is strictly forbidden to lean on the autoclave.
¾
It is strictly forbidden to place your hand or any part of your
body over the door.
·
Wear heat-resistant gloves or use the tray handle to remove the load
from the autoclave
·
On completion of the cycle, the load shall be visual inspected to
ascertain that the load is dry, and that sterilization indicators have
made the required color change.
11.6
Stopping the process and canceling the ERROR message
·
It is possible to stop the program while the autoclave is operating.
Pressing the
START/STOP
key at any stage of the process stops the
operation. If the cycle was aborted before completing the sterilization
stage, it will leave the load unsterilized.
·
At the end of the aborted process (before completing the sterilization
stage),
"Cycle Failed"
message, error message and a warning symbol
are displayed on the screen. Refer to "Displayed Error
Messages/Symbols".
·
Pressing the
START/STOP
key cancels the displayed message and
enables opening the door.
Warning
The load has not completed a sterilization cycle, therefore it is not
sterile. Handle it as contaminated load.
11.7
Cycle by Clock mode (Start Cycle by Clock)
·
This mode enables the operator to define the time of the beginning of
the cycle. The maximum possible delay is 24 hours.
For more information, see sec. 7.7.1. Start Cycle by Clock
Summary of Contents for 2840 EL-D
Page 4: ...Page 3 of 77 14 TROUBLESHOOTING 73 15 SPARE PARTS LIST 77 16 ACCESSORIES 77...
Page 5: ...Page 4 of 77 TABLE OF CONTENT Cont DRAWINGS PAGE NO FRONT VIEW 17 REAR VIEW 18...
Page 26: ...Page 25 of 77...
Page 34: ...Page 33 of 77...
Page 71: ...Page 70 of 77...
Page 72: ...Page 71 of 77 Cap Gasket Strainer element Strainer Housing WATER STRAINER...
Page 77: ......