Page 35
10.3. Cleaning the Water Outlet Strainer
Cautions!
Before proceeding, Make sure that the electric cord is
disconnected and there is no pressure or water in the
chamber.
Warnings
1. The strainer’s cover is HOT
Do not touch the strainer’s cap, mounted on the exhaust
line, during and shortly after operation. Touching the hot
strainer’s cap may cause severe injuries.
2. If maintenance operation is performed while strainer cap
is hot, use heat resistant gloves to avoid injuries.
1.
Open the strainer cap.
2.
Remove the strainer element.
3.
Rinse the strainer with water, using a brush if necessary.
4.
Reinstall the strainer element.
5.
Close the strainer cap.
10.4. Water Sensor Cleaning
It is required that the water sensor be cleaned at least once per week.
The water sensor is located in the rear of the chamber. It is easily cleaned
using a damp cloth or sponge; you may use a mild soapy solution if you like. It
is important to wipe the sides of the sensor as well as the tip, to remove any
dirt or debris that may have built up.
Cap
Gasket
Strainer
element
Strainer
Housing
WATER STRAINER