Discharging a Lithium battery
In this mode, you can set the target per-cell voltage and hence the final voltage (final voltage=cell vol1age'numbcrof cells).
The lowest allowable cell voltage depends on the type ofLithium battery; 2.SOV for Lila, 3.00V for Li Po and 2.00V for Li Fe
per cell. If the battery is connected to the balance port, the charger can monitor the individual cell voltages. The discharge
will stop immediately if any cell falls below the configured final voltage.
Discharge Lithium battery. The left side of the first line set the type of battery(LiPo, Lila
or Li Fe) and the value on the right side shows the final discharge voltage of each cell. The
value on the left side of second line sets the charge current and the value on the right side
of second line sets the cell count and voltage of the battery pack. After setting the current
Dec
and voltage, press Start/Enter for more than 3 seconds to start the next process.
Per-ct>ll final voltage: LiPo(3.00 -4.20V), Lilo(2.50 -4. JOY). LiFe(2.00 -3.60V)
Batt type Start/Enter
Discharge current: 0.05 -7 A, Cell count: I -6S
stop
> 3 seconds
R:03SER S:03SER
CONFIRM (ENTER
The number of cells you set and the processor detects. If the checking result is the same,
it would enter to the next interface; if not the same, the left side of the first line
'R:
X X
SER' shows the number of cells detected by the charger and the right side of the
first line '$:
X X
SER' is the number of cells set by the user. Usually, the auto-detect
number won' t lower than the number set by the user. You should make sure that the
Batt
Xf;
Start/Enter
configured number and the actual number for the banery are the same and then you can
start charging by pressing Start/Enter. If not, press Batt type/Stop to go back to the
previous screen and adjust the setting.
Discharge process. The charger allow its user to alter the discharging current during the
process. Press
St.art/Enter
to make the discharge current blink then press
Inc
►
to
increase
or
press
◄
Dec
to decrease the value and press
Start/Enter
to confirm the
number discharge battery alteration. You can stop discharging at any time by pressing
Batt type/Stop.
Press
Inc ►to
·
of cells current voltage
display each cell' s voltage (sec the balance voltage information) and press
◄
Dec
to
display the General Status information.
Note:
If you con[)ect the balance port at the beginningofthe dischargingprocess, then the balance port
will
monitor each
cell' s voltage, if one of these cells' voltage reaches the termination voltage then the process will terminate with
"balance port low cell vol" . For example in Li Po mode, if one cell' s voltage reaches 3.0V the process will stop
!f you want to avoid this "balance port low cell vol• message. then you can connect the balance port after the discharge
process has started. In that case the process won• t monitor each cell' s voltage just the pack' s voltage and the discharge
process will terminate when the pack voltage reaches the termination voltage(=target_cell_vohageX number_of_cells).
For example in Li Po mode, the discharge process won' t terminate until the pack' s voltage reach N•3.0V.