background image

ELORA 3 STATION CHARGING CABINET 

Owner’s Manual 

7595-0445

Revision  A

Summary of Contents for ELORA 3

Page 1: ...ELORA 3 STATION CHARGING CABINET Owner s Manual 7595 0445 Revision A ...

Page 2: ...RA 3 STATION CHARGING CABINET Owner s Manual 2 IMPORTANT READ AND UNDERSTAND THIS MANUAL BEFORE OPERATION INTRODUCTION KEY FEATURES AND BENEFITS SPECIFICATIONS WARNINGS PRECAUTIONS ORDERING INFORMATION 3 4 4 6 13 14 CONTENTS ...

Page 3: ...SONAL INJURY ELORA ACCEPTS NO RESPONSIBILITY FOR ANY INJURY OR DAMAGE ASSOCIATED WITH THE USE OF BATTERIES NOT MANUFACTURED OR BATTERIES SERVICED OTHER THAN BY ELORA SUCH USE WILL VOID ANY WARRANTY Special precautions and handling instructions are contained in this manual and should be strictly adhered to for safe and reliable operation Contact ELORA Customer Support Group at 1 888 77ELORA or cust...

Page 4: ...LED indicates that the battery has been completely charged is ready for use and has the highest capacity run time This is the battery that should be removed first Only one battery will indicate green at a given time Once this battery has been removed the next fully charged battery if available will illuminate green indicating that it is ready for use and has the highest capacity run time This assu...

Page 5: ...lt Elora Customer Support Group for information on disposal recycling of the Elora Charging Cabinet and its associated components and or accessories OPERATING ENVIRONMENT TEMPERATURE RANGE 0ºC to 30ºC 32ºF to 86ºF RELATIVE HUMIDITY 20 70 non condensing PRESSURE 985 hPa 1040hPa TRANSPORTATION STORAGE ENVIRONMENT TEMPERATURE RANGE 20ºC to 40ºC 4ºF to 104ºF RELATIVE HUMIDITY 20 70 non condensing PRES...

Page 6: ...ent must be three conductor and be correctly wired to provide connection to earth ground Improperly wired extension cords are a dangerous electrical hazard The fact that the equipment operates satisfactorily does not imply that the power point is properly grounded and that the installation is completely safe If any doubt exists about the correct grounding of the power point consult a qualified ele...

Page 7: ... ensure that over charge conditions are avoided FUL This determination is made when a fully charged DIGITAL battery is returned to a charger within specified parameters of time temperature and battery voltage The DIGITAL battery communicates its fully charged condition and the charger confirms the parameters and immediately indicates a fully charged condition without additional verification TEMPER...

Page 8: ...the charger and the battery only Elora Series batteries should be used in this charging cabinet SHUTDOWN PROCEDURE If the unit were to require shut down the ON OFF switch to the unit is mounted on the front panel in the lower right corner The O indicates that the power is OFF This switch in the OFF position isolates the supply mains from the device The system may continue to run if batteries are m...

Page 9: ...MUST BE LEVEL AND SPACED APPROPRIATELY BEFORE THE CABINETS ARE INSTALLED ITEMS SHOULD NOT BE PLACED ON THE TOP OF THE CABINETS USE CAUTION WHEN HANDLING SHEET METAL PARTS THE EDGES MAY BE SHARP CAUTION Make sure the wall meets the load capacity requirements for the cabinet being installed The wall the unit is to be mounted to shall be thick drywall or greater with studs spaced 16 on center apart f...

Page 10: ...cabinet see figure 1 3 Remove these two screws do NOT discard 4 Push down on the mounting plate on the back of the cabinet This should allow it to be removed from the cabinet 5 Determine the vertical position at which the top of the cabinet is to be located This location should be aligned with a stud within the wall Failure to do so could result in the cabinet becoming dislodged from the wall and ...

Page 11: ...1 8 wide This will allow for the cabinet to fit inside of the opening and for the mounting bezel to attach to the wall without any open spaces around the cabinet to be visible Use caution when removing sheetrock to ensure that no existing wiring or plumbing within the wall is disturbed 6 After creating the rough opening use the mounting bezel as a template and mark the locations for the bolts 7 Dr...

Page 12: ...www elorapower com ELORA 3 STATION CHARGING CABINET Owner s Manual 12 LINE DRAWINGS SPECIFICATIONS ...

Page 13: ...e Remove applicable knockout Assemble a UL listed conduit con nector in the opening A Removable Retaining Nut B Strain Relief Feed the flexible conduit through the strain relief allowing enough slack to easily attach wiring to the device Tighten strain relief screw against the flexible conduit Knockout ...

Page 14: ...www elorapower com ELORA 3 STATION CHARGING CABINET Owner s Manual 14 SPECIFICATIONS Complete wiring as shown below ...

Page 15: ...n the patient environment 10 Never attempt to charge any battery that is damaged in any way 11 WARNING To avoid risk of electric shock this equip ment must only be connected to a supply mains with protective earth 12 WARNING No modification of this equipment is allowed 13 Do not manually depress and or override the cabinet door s interlock switch 14 WARNING This device is designed to conform to El...

Page 16: ...AMAGE RESULTING FROM ACCIDENTS DISASTER NEGLECT MISUSE IMPROPER INSTALLATION IMPROPER OR UNAUTHORIZED SERVICE OR MAINTENANCE UNAUTHORIZED REPLACEMENT PARTS OR ATTACHMENTS OR DYSFUNCTION OR MALFUNCTION OF OR CAUSED BY ANY OTHER PRODUCT OR DEVICE Misuse includes any use of the Product in other than its intended application including the use of this Product with any charging device or accessory not m...

Page 17: ...er Support customersfirst elorapower com 1 888 77ELORA Call 1 888 77ELORA or email us at customersfirst elorapower com Visit our website at www elorapower com Copyright 2019 Elora International All rights reserved ...

Reviews: