Setting
Setting RFID interface parameters via the web server
66
Hans Turck GmbH & Co. KG | T +49 208 4952-0 | F +49 208 4952-264 | [email protected] | www.turck.com
Designation
Meaning
HF: Address for ScanStart
method
Start address of the UID or USER memory area on the tag to be
read
Default setting:
0
HF: Length for ScanStart
method
Number of bytes to be read with the
ScanStart
method
Default setting:
8
HF bus mode: Activate
read/write head …
Activates or deactivates the read/write head with address .....
Default setting:
Off
8.2.2
HF applications – selecting the tag type
If the
ScanStart
parameter is set to Read, a tag must be selected beforehand. Automatic
tag detection is not possible.
In multitag applications select a tag type for the execution of the
read
and
write
meth-
ods. Automatic tag detection is not supported for the
read
and
write
commands in mul-
titag mode.
The “RF communication error” is generated if the parameters of a tag located in the detection
range of the read/write head do not match the selected tag type. In this case check the set tag
type.
The tag type does not have to be selected in single tag applications and for the execution of in-
ventory commands or scan methods in multitag applications if the read/write head detects the
tags automatically.
Tag
Firmware version
Read/write head
Selectable
Automatic
detection
possible
Displayed in web
server
1: NXP Icode SLIX
≥ Vx.91
x
x
x
≤ Vx.90
x
x
x
2: Fujitsu MB89R118
≥ Vx.91
x
x
x
≤ Vx.90
x
x
x
3: TI Tag-it HF-I Plus
≥ Vx.91
x
x
x
≤ Vx.90
x
x
x
4: Infineon SRF55V02P
≥ Vx.91
x
x
x
≤ Vx.90
x
x
x
5: NXP Icode SLIX-S
≥ Vx.91
x
x
x
≤ Vx.90
x
–
x
6: Fujitsu MB89R119
≥ Vx.91
x
x
x
≤ Vx.90
x
–
x
7: TI Tag-it HF-I
≥ Vx.91
x
x
x
≤ Vx.90
x
–
x
8: Infineon SRF55V10P
≥ Vx.91
x
x
x
≤ Vx.90
x
–
x
11: NXP Icode SLIX-L
≥ Vx.91
x
x
x
≤ Vx.90
x
–
x
12: Fujitsu MB89R112
≥ Vx.91
x
x
x
≤ Vx.90
x
–
x
13: EM4233SLIC
≥ Vx.91
x
x
x
≤ Vx.90
x
–
x