Operation
LEDs
98
Hans Turck GmbH & Co. KG | T +49 208 4952-0 | F +49 208 4952-264 | [email protected] | www.turck.com
TP0…TP3 LEDs
Meaning
Off
No tag within the detection range
Green
Tag present at read/write head
Green flashing
Tag present at read/write head, command is processed
Red/green flashing
(1 Hz)
Connection with DTM. No connection to controller active.
Red
Diagnostics present
CMD0…CMD3 LEDs
Meaning
Off
Read/write head off
Green
Read/write head on
Green flashing
BUSY (command active)
Red flashing
Interface memory full
Red
Error in the data interface
RFID channel LEDs
Meaning
TP… and CMD… flash
simultaneously
Overload of the auxiliary voltage
TP… and CMD… flash
alternately
Parameter error
DXP channel LEDs
Meaning (input)
Meaning (output)
Off
No input signal
Output not active
Green
Input signal present
Output active (max. 2 A)
Red
–
Actuator overload
Red flashing (1 Hz)
Overload of sensor supply