V02.00 | 2021/11
65
RFID channels – meaning of the parameters
Default values are shown in
bold
type.
Designation
Meaning
Operation mode
n
HF/UHF mode
n
HF bus mode
HF: Select tag type
0: Automatic HF tag detection
1: NXP Icode SLIX
2: Fujitsu MB89R118
3: TI Tag-it HF-I Plus
4: Infineon SRF55V02P
5: NXP Icode SLIX-S
6: Fujitsu MB89R119
7: TI Tag-it HF-I
8: Infineon SRF55V10P
9: Reserved
10: Reserved
11: NXP Icode SLIX-L
12: Fujitsu MB89R112
13: EM4233SLIC
Read/write heads with firmware from Vx.91 also support:
14: NXP SLIX2
15: TI Tag-it HFI Pro
16:Turck sensor tag
17: Infineon SRF55V02S
18: Infineon SRF55V10S
19: EM4233
20: EM4237
21: EM4237 SLIC
22: EM4237 SLIX
23: EM4033
HF: Bypass time (*ms)
Bridging time in ms, adjustable from 4…1020 ms,
Default setting:
200 ms
Termination active
Activates or deactivates the bus termination.
Default setting:
On
HF: Autotuning read/write
head
Activates or deactivates the automatic tuning of the read/write
heads.
Default setting:
Off
HF: Multitag
In HF applications several tags can be read or written in the detec-
tion range. Multitag mode is not possible in combination with the
ScanStart
method. A
Scan
operation outputs the UIDs of all tags
in the detection range. The
LastScanData
variable always shows
the last UID read.
Default setting:
Off
HF: Command for ScanStart
method
n
Inventory
: The read/write device searches for tags in the detec-
tion range and reads the UID or EPC.
n
Read: the read/write device reads the data (max. 64 bytes) of
the tags in the detection range.
If the
ScanStart
parameter is set to Read, a tag must be selected
beforehand via the
HF:
Select tag type
parameter. Automatic tag
detection is not possible.