DESCRIPTION OF ALARM INDICATOR LIGHTS
Battery charge alarm
It is possible to work with the machine for up to
180 minutes (approx. 3 hours) after this alarm
has been given so that the work in progress may
be completed.
It is impossible to work after this time has
elapsed because the engine automatically cuts
out after it has been started.
It is important to start recharging operations
to prevent the battery from becoming totally
discharged. (Request the help of an authorised
after-sales service centre.)
Engine oil pressure alarm
This alarm automatically cuts out the engine
after a variable time of approx. 10 seconds.
Top up the oil level and check for leaks.
Diesel fuel level alarm
This alarm is given when the level in the tank falls
below the minimum mark.
The engine automatically cuts out after 10
minutes. The engine may be restarted with the
risk of fi nishing the diesel completely, which
would lead to subsequent diffi culty in restarting
even after having fi lled up with fuel.
Hydraulic fl uid temperature alarm
This alarm automatically cuts out the engine
after a variable time of approx. 8 seconds.
If the engine cuts out due to an alarm, the situation is
shown on the display as follows:
The engine is switched off through the diesel solenoid
valve. All the other functions remain active and the LED
(indicator light) relating to the alarm that has caused the
engine to stop remains lit.
Press the machine start button
(c1) ON/OFF
to return to
the original display page.
• Maintenance work
The machine is programmed to request periodic
maintenance: the fi rst servicing is scheduled after 50 hours
of operation while subsequent maintenance is scheduled
at specifi ed intervals (see page 30).
• Operating test
The machine has an operating test mode in which the
various devices may be controlled and the input status
displayed with the engine switched off.
To enter this operating mode press the
button
(g4)
when the writing Start Engine:
Start appears on the display.
The start engine phase is thus jumped to enter directly into
the operating phase with normal indication on the display.
It is then possible:
- to control the various devices (mixer, mortar pump,
vibrating sieve) using the buttons on the control panel
and to check that the relative solenoid valves activate;
- to check the status of the inputs (micros and alarms),
observing the red indicator lights on the control panel.
• Enabling and disabling the ACCESS CODE
The access code may be disabled and then enabled again
directly by the operator.
The operator is responsible for all the
consequences of disabling the access code
(use of the machine by any other person).
The enabling/disabling procedure is as follows:
- Enter the operating section, specifying the access code.
The display appears as follows
- Press key
F1
.
- The message for changing the parameter related to the
Access Code now appears on the display.
Proceed in sequence using the keys
(g3-g4)
.
To change the parameter value:
0 = disabled access code
1 = enabled access code
Save the parameter value and exit.
g4
g4
g3
Reg: >
< 38
Allarm: Motor OFF
Reg: >
< 20
Vbat: 11.4
Motor On: START
[ , , F2]
1
Enable Access Code
Summary of Contents for PRO H CL
Page 35: ...35 SPARE PARTS GENERAL CATALOGUE ...
Page 42: ...42 2 6 7 9 7 4 8 6 5 4 5 1 3 3 15 12 14 10 13 11 TABLE 5 VIBRATING SIEVE N 05 ...
Page 46: ...46 TABLE 13 ELECTRIC BOARD N 07 1 2 3 ...
Page 50: ...50 TABLE 9 ACCESSORY BOX code 201 114 N 09 1 2 5 3 4 14 15 12 11 13 7 8 10 9 Ø 60 6 ...
Page 52: ...52 ...
Page 53: ...53 WIRING DIAGRAMS ...