33
Stator clamp too tight.
Working pressure too high.
Hose plugged.
Stator wrongly set.
• Allentare strettore.
• Modifi care l’impasto o ridurre la
lunghezza delle tubazioni o utilizzare
tubazioni di diametro maggiore.
• Impasto non corretto,
modifi care l’impasto.
• Sosta troppo prolungata, ridurre i
tempi di sosta.
• Statore non registrato correttamente,
registrare strettore.
• Registrare strettore
6.2 - OPERATOR INTERVENTION
Mortar pump blocked
(oil pressure gauge shows 210
bar)
No material comes out
from the delivery hopper
P
ROBLEMS
C
AUSES
R
EMEDIES
6.3 - INTERVENTION BY AUTHORIZED PERSONNEL
For anomalies that are different from the ones previously mentioned, contact the authorized after sales service.