EN
BM 30
IS13/02 - 561291
7 - USE AND OPERATION
7
-
Pag. 6/13
THIS MANUAL IS PROPERTY OF
-
ANY TOTAL OR PARTIAL REPRODUCTION IS STRICTLY FORBIDDEN
Cap.
• Hydraulic oil temperature alarm
This alarm automatically switches pumping off.
The machine remains on to allow the oil to cool down.
• Engine cooling liquid temperature alarm
This alarm automatically switches the engine off after a variable time between 1 and 100 seconds.
The alarm appears on display:
Alarm: Motor OFF
BTM 3P4
Operation indicator
A LED (above the relative key) is associated to each function: the LED is on when function is active.
7.5 MACHINE
SWITCH-ON
*indicating the installed software and machine's serial number.
- Package an adequate amount of grout (water and cement):
• pumping up to 20 m - 40/50 litres
• pumping beyond 20 m - 50/80 litres
- Check the emergency button (FIG.28-REF.1) is not engaged.
- Press the machine start ON/OFF key to start using it.