Piping line layout
BM 30 can pump horizontally, upwards and downwards. Below are some general rules for the different types of layouts.
1
FIG.11 FIG.12
- Horizontal
pumping
Lay piping as wanted and connect it to the first section shown in FIG.11 to pump material horizontally.
- Vertical
pumping
The vertical piping section must be fixed and supported using the appropriate collars (FIG.12-REF.1).
- Downward
pumping
The downward piping section must be fixed and supported using the appropriate collars (FIG.13-REF.1).
Arrangements must be made to stop the concrete fall in the downward section (e.g. assemble a bend or S-bend - as in FIG.13
or make tilted sections). For this type of layout, we recommend lubricating pipes with grout as follows:
- introduce two wash sponges in the piping's initial section (FIG.14).
- Pump the grout. The entire internal surface of the downward section will, in this way, be lubricated. Introduce more sponges
and more grout if the downward section is particularly long.