5.1 PLACEMENT
Place the machine horizontally; the maximum admitted longitudinal and transversal slope is 5° (FIG.09).
140 cm
140 cm
120 cm
120 cm
FIG.09 FIG.10
- Place the machine in the most suitable point on site for best use of the piping's action range.
- Brake the machine and block the wheels using appropriate parking wedges.
- Ensure the machine rests on the side stabilising feet.
Clear passages (FIG.10) from any encumbrance and a floor surface without holes or dangerous projections must
be present around the machine.
Do not use the wheel as support during work: the machine must rest on the side stabilising feet and the
wheels, and this position must be stable.
5.2 PIPING
Lay piping limiting their length as much as possible (transport and wear times are reduced), checking it is in good condition.
Use flexible rubber hoses only in the last piping section and with length of not more than 4 m; the use of
rubber hoses in other position along the piping, jeopardises pumping (water separation from concrete) and
increases risk of clogging.
Use only TURBOSOL PRODUZIONE S.p.A. original piping and fittings or those from companies expressly
authorised by them. TURBOSOL PRODUZIONE S.p.A. will not, in any event, answer for any injuries to people or
damages to property
determined by the use of non-original piping or fittings.
Ensure the internal surface of the used flexible hose end is not torn or deteriorated, before pumping. Deforming
of the internal surface may cause dangerous cloggings.