in order to ensure that the sauna is ready for use. If the door is
open or if the reset button has not been pressed, the sauna
will not be heated.
Install the door switch outside the sauna room at the top edge
of the door at least 300 mm from the door’s inner corner. In-
stall the switch in the doorframe and the magnet in the door.
The distance between the switch and the magnet must not
exceed 18 mm. The reset button should be installed outside
the sauna room in a suitable place.
GND
Door
Magnetic switch
GND
Reset
Reset button
ON/OFF SWITCH
J14 GND
J14 on/off
On/Off button
Startup takes place when the electrical circuit is completed.
When the gap is closed, the sauna will be switched on with the
previous sauna session’s temperature setting. When the circuit
is broken, the sauna heater is switched off.
More detailed installation and operating instructions are sup-
plied with the product itself and are also available at website
www.tulikivi.fi.
CUT-OFF CLOCK
Tulikivi sauna heaters have a built-in cut-off clock that re-
stricts the heating time as follows:
1. Apartment block shared saunas: can be switched on and off
without restriction over a 12-hour period. If the heater has
been in continuous use for 12 hours, it will revert to stand-
by status and will be operable again after a 6-hour break.
(DIP switches set at 100)
2. Hotel saunas: the default 24-hour setting for the sauna
heater is 4 hours on, 6 hours off, 8 hours on and 6 hours off.
(DIP switches set at 010)
3. For home use, the maximum time the sauna heater can be
on is set at 6 hours. (DIP switches set at 001)
4. In supervised commercial use, there is no cut-off clock.
(DIP switches set at 000)
The operation of the cut-off clock is determined using the DIP
switches on the relay card. FOR HOME USE, THE CUT-OFF
MUST ALWAYS BE USED AND THE DIP SWITCH SETTING
MUST NOT BE CHANGED.
THERMOCOUPLE INSTALLATION
(ACCESSORY)
1. Connect the thermocouple to the sauna
heater control card.
(NEG) red
(POS) yellow
2. Pass the thermocouple through the hole near the top edge
of the connection box.
3. First fill the stone compartment with sauna stones up to the
height of the thermocouple.
4. Push the end of the thermocouple right to the end of the
installation pipe.
5. Position the installation pipe in the stone compartment. At-
tach the pipe by slotting it in place in the hole in the stone
compartment wall.
Note: the pipe must not touch the heating elements.
6. Place the rest of the sauna stones in the stone compartment.
OTHER CONNECTIONS: DOOR SWITCH AND RESET BUTTON
(OPTIONAL ACCESSORY)
In order to use the heater’s remote startup function, the door
switch and reset button must be installed. When the heater is
set to switch on with the weekly timer, the system checks that
the sauna door is closed and the reset button has been pressed
TEMPERATURE SENSOR INSTALLATION
The temperature sensor should be screwed to the wall above
the heater about 50 mm from the ceiling, or directly to the
ceiling above the heater (see Figures 3 and 4 on page 20). The
ceramic cover for the sensor should then be pressed into place.
Make sure that the air intake is sufficiently far away from the
sensor (recommended minimum distance 1 m).
yellow
(12 Vdc)
green or blue
(IN)
brown or red
(A in)
white
(5Vdc)
Resetting the overheat shut-off
FIGURE 6
Temperature sensor
Temperature sensor
Min.1000
Min.500
360
180
Omnidirectional (360°) air intake vents must be at least 1000
mm from the temperature sensor. Air intake vents with a baffle
(180°) must be at least 500 mm from the temperature sen-
sor. Air from intake vents must not be directed at the temper-
ature sensor.
Make sure that the air intake vent is sufficiently far away from
the sensor (recommended min. distance 1 m).