ENG
20
The installation of the
thermocouple (accessory)
is shown on page 24.
FIGURE 4
The temperature
sensor (supplied as
standard) measures
the temperature in
the sauna room.
The temperature
sensor is installed on
the wall in line with
the mid-point of the
heater, or on the ceil-
ing above the heater.
The installation of the
temperature sensor is
shown on page 23.
Installation instructions
Only one electric sauna heater may be installed in the sauna room. The safety distances indicated in the table must
be followed when installing the heater in the sauna. The minimum distances must be followed even if the wall mate-
rial is fireproof. The heater’s installation pedestal must be strong enough to carry the weight of the heater and its
stones. Panelling alone is not sufficient for installation. If any problems arise or you have questions related to instal-
lation, please contact our technical support, tel. 040 3063 100.
power
size of sauna room
safety distances
recommended
amount of
sauna stones
k
W
m
3
minimum
height
mm
Around
the
heAter
,
to
A
height
of
900
mm
Around
the
heAter
,
Above
A
height
of
900
mm
minimum
to
ceiling
mm
Approx
.
kg
4,5
3-6
1900
20
50
1200
35
6,0
5-9
1900
20
50
1200
35
9,0
8-13
1900
20
50
1200
35
TABLE 1
SAFETY DISTANCES
Safety distance from
the wall
Safety distance
between integrated
heater and bench,
up to a height of
900 mm
The temperature
sensor is installed on
the ceiling above the
heater
FIGURE 2
FIGURE 3
20 mm
50 mm
50 mm
150 mm
1900 mm
20 mm
50 mm
Summary of Contents for HALLA E