ENG
21
BUS+
1A
1 2 3 4 5 6
N
L1
L3
L2
N
U
V
W
L1
L2
L3
1
2
3
Control
OUT1
N
L
1.
2.
3.
4.
5.
6.
1. KNX-liitäntä/KNX-interface/KNX-anslutning/KNX-Anschluss/
Интерфейс
KNX
2. Ovikytkin /Door switch/Dörr brytare/Türschalter/
Дверной
выключатель
3. Ovikuittaus /Door reset switch/Dörr nollställning/Rücksetzschalter Tür/
Кнопка
сброса
4. On-Off kytkin/On-Off switch/On-Off brytare/On-Off-Schalter/
Выключатель
On-Off
5. Touch Screen-liitäntä/Touch Screen interface/Touch Screen anslutning
/
Touch Screen-Anschluss/
Интерфейс
Touch Screen
6. Termopari/Thermocouple/Termoelement/Thermoelement/
Термопара
7. Syöttö/Power input/Nätet/Stromeinspeisung/
Питание
8. Ulostulo1 (1A)/Output1(1A)/Utgång1 (1A)/Stromabgabe1 (1A)/
Выход
1 (1
А
)
9. Sähkölämmityksen vuorottelu/Signal contact/El. förreglering av annan el. förbrukare/
Signalkontakt/
Чередование
нагрева
электрической
каменки
10. Lämpöanturi/Thermal probe/Värmesond/Temperatursensor/Термостат
7.
8.
out1
PE
SS184
BUS-
GND
Door
GND
Reset
GND
ON/OFF
A
B
POS.
NEG.
A in
5V dc
IN
12V dc
OUT2
55
9.
5.
10.
CIRCUIT DIAGRAM
1. KNX connection
2. Door switch
3. Door reset
4. On/off switch
ELECTRICAL CONNECTION
The electrical work for the sauna heater may only be per-
formed by a qualified electrician authorised to undertake
such work, in accordance with the relevant regulations. The
heater should be connected to the mains semi-perma-
nently. The coupling box must be splashproof and placed at
a minimum of the safety distance from the heater and at a
height of no more than 500 mm above the floor.
The connecting cable must be a rubber cable of type
H07RN-F or equivalent. The heater must not be connected
using a cable with PVC insulation. The specifications for the
connecting cables and fuses are presented in Table 2. Do
not connect the heater’s power feed through an earth
leakage circuit breaker (ELCB). In the final inspection of
electrical installation work, the heater’s insulation resist-
ance test may show leakage. This is due to moisture having
been concentrated in the heating elements’ insulating ma-
terial during storage or transport. The moisture can be re-
moved from the heating elements by running the sauna
once or twice. The temperature sensor should be installed
in accordance with Figures 3 and 4. Make sure that the air
intake is sufficiently far away from the sensor (recom-
mended minimum distance 1 m, see page 23).
TABLE 2
power
electrotechnical data
kW
fuse
heater connection cable
h07rn-f/60245 iec mm2
4,5
3
x
10 A
5
x
1,5
6,0
3
x
10 A
5
x
1,5
9,0
3
x
16 A
5
x
2,5
INSTALLATION DIAGRAM
Tulikivi Touch Screen
Touch Screen
SS298, IP54
4x0,25 (6 m)
400V 3N
Heater
IPx4
5. Touch screen
6. Thermocouple
7. Power input
8. Outlet 1 (1a)
9. Alternation of electric heating
10. Temperature sensor
Temperature sensor