AB Connectors Limited
Specification No. 528
ABCIRP Connector Series
Assembly and wiring Instructions
AB Connectors Limited Issue 9: July 2010
Page 20 of 41
8.2
Method: A: Termination Procedure For In-line Wire Bundles
8.2.1
Method A uses two stainless steel securing bands that concentrically close to
mechanically grip and electrically terminate the overall shield to:-
.
• The connector backshell, (RFI / Heat Shrink Adaptor)
.
• The wire bundles or multi-core cables.
8.3
Procedure for a Fixed Connector with (SCHSA).
8.3.1
Cut the braid sock to the required length and remove inner storage tube. Fold one
end of the Braidsock back inside itself by approximately 15 to 20mm.
as shown right. This provides a clean edge without sharp sections.
8.3.2
Slide sock over threaded portion of RFI Adaptor.
8.3.3
Terminate braid sock to the RFI adaptor, using a securing band
shown in Appendix C.
Termination of Braid Sock To RFI Adaptor
8.3.4
Strip cable outer insulation exposing the screen for a length of 70mm, and trim off all
of this exposed screen.
8.3.5
Strip the cable outer insulation to a length of 170mm from the end of the cable, as
shown below; which then gives a braid length of 100/125mm.
SCHSA Insulation Strip Lengths