VarioStress
ANTI-JAM SYSTEM
An automate
(3)
controls the anti-jam
system’s electro valve. It is with the
10Amp and 1 Amp protection fuses
(4)
and
(5)
in the conduit box behind
the engine on the front side of the
hopper.
The primary circuit’s 10Amp
protection fuse
(6)
is in the watertight
fuse-holder compartmentalized on the
starter cable.
PETROL DIESEL
D E S C R I P T I O N A N D
M A N I P U L A T I O N
See Use of the machine in manual mode on page 53
+ intervention technician p.46
The distance between
the speed controller
(
1
)
and the pulse device
(
2
)
is
0,16 to 0,20 in (4
to
5
mm)
.
The PREMIUM is equipped with a controller of the rotation of the rotor that is linked to
an automat. Hence, we can prevent the machine from being blocked: permanent
information about the rotating speed of the rotor is being sent to the VarioStress. When the
rotor speed falls below a factory-set threshold, the hydraulic supply of the feed is
interrupted. The feed and belt will stop, the machine will no longer be fed material and the
engine can reach its working speed agian (3600T/mn). When the speed exceeds the lower
threshold, the feed roll and belt are supplied with oil again and the engine starts running
again.
There are three anti-obstruction settings: see the next page