PREMIUM22P
2014-10-08
30
CONTROL BLADES AND HAMMER INSERTS
M A I N T E N A N C E
Remove the ignition key before proceeding.
ACCESS TO ROTOR
:
In order to gain access to the rotor:
-Remove the two Nylstop nuts
-Open the chute by rotating it on the two
articulations
For easier maintenance, henceforth the hammers are mounted without
lubricator but with special wear rings.
The lack of lubricators on the hammers however should not stop you from
inspecting the hammer discs and blades on a regular basis.
Upon inspection, check whether the
hammers are rotating freely.
In case there is a coarseness, spray
penetrating grease onto the axles and
tap the hammer(s) using a mallet.
Frequency of inspections
:
- control blades and hammer inserts : 50h
- Verification wear rings hammers: 200h