Control unit setup for Power Blind installation
•
Locate DIP switch block on the control unit labeled “S2”. (See main
wiring diagram on page 7.) Set DIP switch #4 to the “on” position.
(Important: Do not change any other switch positions!)
S2
S2
S2
S2
1
2
3
4
5
6
on
off
•
Consult blind installation instructions for proper blind motor polarity.
Locate the positive wire to open the motorized blind. Connect it to the
“Grey” terminal on terminal block #12. (See main wiring diagram.)
Note:
•
If unable to determine the positive wire to open the motorized blind,
the blind motor can be connected in either orientation. However, if
the blinds open in the opposite direction from the button pressed,
the two wires will need to be reversed.
•
When the blinds are used in combination with the HPI “Open”
function, the blinds will open automatically before the skylight is
opened. This is because this feature is often used for smoke
evacuation when connected to a smoke alarm.