background image

SRS and XRS EID Stick Reader 

Issue 2, 02/2013 

27 

Replace the case gasket taking care 

that is is placed in the groove evenly and that it is located 

correctly around holes and pins. The interface with the tube gasket is critical  

 

Figure 5 Interface between the case gasket and tube gasket 

Reconnect the FFC connecting the main module and the display module. See 

Using flat flexible 

circuit (FFC) cables and connectors 

on

 

page 23. 

Close the case. See

 

page 24. 

Replacing the tube gasket 

Open the case. See page 24. 

Remove the main module and FRP tube assembly from the bottom case. See page 28. 

Remove the tube gasket by sliding it off the FRP tube. 

Slide the new tube gasket back over the FRP tube. Note that it must be orientated as shown in 

Figure

 5

.

 Make sure that the location lugs are engaged in the holes in the tube. 

Refit the main module and FRP tube assembly in the bottom case. See page 28. 

Close the case. See

 

page 24. 

Replacing the battery 

Unscrew the battery compartment cover and remove the battery. 

Write the installation date on the new battery with a permanent marker. 

Insert the battery with the metal battery terminals inserted first towards the main module. 

Replace the battery compartment cover. 

Check that the stick reader operates and place on charge for 3 hours.  

Summary of Contents for XRS

Page 1: ...Unexpected behaviour during use 12 EziLink problems 14 LCD display problems XRS EID Stick Reader only 15 Connection problems 16 Testing the stick reader 17 Testing the power connection XRS EID Stick R...

Page 2: ...settings on the stick reader itself XRS EID Stick Reader only 33 Changing the stick reader settings using EziLink 33 Changing the file format 34 Charging the battery 34 Updating the software 34 Resto...

Page 3: ...mponent and may result in faults developing within that component over time When working on a stick reader ensure that correct anti static procedures are used 1 Use a wrist band and earth strap 2 Work...

Page 4: ...xample Loctite 243 Test tags FDX and HDX test tags Main module Known good sample Display module Known good sample Computer Windows XP or later with EziLink and Hyperterminal installed EziLink is suppl...

Page 5: ...SRS and XRS EID Stick Reader Issue 2 02 2013 5 Parts diagram...

Page 6: ...rial Adaptor 814643 provides connection to a PC or On its own provides connection to a 3000 series weigh scale indicator 819821 2 Charging kit Both models 1 x multi region power adaptor 1 x SRS XRS ad...

Page 7: ...case beeper and SRS name plate 822639 2 Bottom case 1 x bottom case assembly consists of bottom case gasket for battery compartment cover 4 pin serial connector and loom vent vibration motor dust cap...

Page 8: ...y Try replacing the serial connector and loom See page 32 Main module faulty Replace the main module See page 28 XRS EID Stick Reader only Battery goes flat too soon even though the charging symbol on...

Page 9: ...tenna broken poor tuning Try replacing the main module assembly which includes the antenna See page 28 Faulty module Replace the main module See page 28 Both models Stick reader doesn t turn on Batter...

Page 10: ...D Stick Reader only To change the Read Mode see Changing the stick reader settings using EziLink on page 33 Reading Tags tab Read Time setting Both models The stick reader keeps on scanning for a tag...

Page 11: ...e Read Mode see Changing the stick reader settings using EziLink on page 33 Reading Tags tab Read Time setting Both models The stick reader doesn t beep when a tag is scanned or the stick reader is sw...

Page 12: ...e battery contacts may be misaligned Replace the battery See page 27 Both models The stick reader won t record an EID twice in a session This is normal behaviour when default settings are applied XRS...

Page 13: ...memory is full 20 000 scan capacity the stick reader will begin to overwrite the oldest scan records Transfer sessions to a PC using EziLink See Backing up customer data on page 22 Clear unwanted sess...

Page 14: ...Excel as scientific numbers e g 982000000123456 displayed as 9 82E 14 EziLink has been set to import sessions in a NLIS or csv format and the EID information doesn t display correctly when opened in E...

Page 15: ...on the stick reader itself on page 33 LCD display has missing pixels Faulty Display FFC flat flexible circuit cable Test the LCD See page 20 Try replacing the Display FFC flat flexible circuit cable...

Page 16: ...reader must be connected to the PC and switched on before EziLink is launched 1 Ensure that the stick reader is connected to the PC properly 2 Turn on the stick reader 3 Launch EziLink Another applic...

Page 17: ...connection are both functioning correctly If not then the SRS XRS Serial cable or the USB Serial adaptor may be faulty Check using a known good cable adaptor Testing the Bluetooth wireless connection...

Page 18: ...hold both buttons to go into the menu Go down to 4 BLUETOOTH using the Scroll button Change the setting to MANUAL using the READ button 3 If you have not done so already pair the PC to the stick read...

Page 19: ...re you start EziLink so that it s ready to be found If you turn on the stick reader more than a minute after starting EziLink EziLink may resume searching the COM ports This can be prevented by settin...

Page 20: ...ened if the battery remains discharged for long periods Lithium Ion batteries naturally lose some of their capacity each year depending on the temperature and battery state and eventually need to be r...

Page 21: ...f the battery using a multi meter If less than 6 0 V replace battery See page 30 4 Plug battery into battery test load 3 3 5 W and 4 7 5 W in series After one hour the battery voltage should be greate...

Page 22: ...M or DVD and return this to the customer with the stick reader Notes The stick reader must be on before EziLink is launched otherwise EziLink will not connect with the stick reader Installing and usin...

Page 23: ...damaging the tail on the FFC or the FFC connector on either the display module or the main module Do not force the FFC tail out of the FFC connector The track on the FFC has a pitch of only 0 5 mm 1 5...

Page 24: ...lightly to the case gasket so gently rocking should be able to remove it 5 Turn over the top case and lie it side by side with the bottom case Figure 1 Case open To close the case Stick readers are of...

Page 25: ...rew may be replaced by a No 4x 5 8 pan pozi stainless steel screw long case screw supplied in the screws kit Do NOT use a variable speed drill to tighten or undo the screws Replacing the gasket for th...

Page 26: ...the case gasket 1 Open the case See page 24 2 Disconnect the FFC from the main module See Using flat flexible circuit FFC cables and connectors on page 23 3 Using your fingers gently peel away the ca...

Page 27: ...be assembly from the bottom case See page 28 3 Remove the tube gasket by sliding it off the FRP tube 4 Slide the new tube gasket back over the FRP tube Note that it must be orientated as shown in Figu...

Page 28: ...disconnect the vibration motor loom Both models Disconnect the power loom 4 Manually remove the screw securing the main module to the bottom case Figure 6 Location of two looms and main module securin...

Page 29: ...To remove the display module 1 Open the case See page 24 2 Disconnect the FFC from the main module See Using flat flexible circuit FFC cables and connectors on page 23 3 Manually remove the 5 screws...

Page 30: ...to 0 5 Nm 4 lbf in 6 Reconnect the FFC to the main module See Using flat flexible circuit FFC cables and connectors on page 23 7 Close the case See page 24 8 XRS EID Stick Reader only Test the LCD See...

Page 31: ...real time clock battery XRS EID Stick Reader only Caution Replacing the real time clock battery will reset the date and time Reset the date and time before returning the stick reader to the customer...

Page 32: ...odule See page 29 2 Disconnect the other end of the FFC connected to the main module See Using flat flexible circuit FFC cables and connectors on page 23 3 Discard the old FFC and replace it with a ne...

Page 33: ...g appears advising that this process will remove all records from all sessions all VID EID pairs and all alerts from the stick reader 5 Click Clear Everything The data is cleared from the stick reader...

Page 34: ...sv This is a csv file suitable for uploading to the NLIS database applicable in Australia only NAIT This is a csv file suitable for uplading to the NAIT database applicable in New Zealand only Changin...

Page 35: ...USB to Serial Comm Port COMxx where xx is the COM port number Windows XP Click on Start Settings Control Panel to access the Device Manager Double click on the System icon click on the Hardware tab th...

Page 36: ...be hidden To display hidden files and folders see the help menu for your platform Windows 7 or Windows XP Double click on the ini file and modify the string FirmwareUpdateDevice to read FirmwareUpdat...

Page 37: ...est Ltd service trutest co nz From Distributor Tru Test Ltd representative Date Return authority RA number Warranty Yes No Product returned XRS EID Stick Reader SRS EIDStick Reader Serial number Part...

Reviews: