Model 4590
4–17
3
3
.
.
Gently slide the gauge to the right until the source rod is in
contact with the side of the hole.
4
4
.
.
Press ENTER to start the measurement. The gauge displays:
NOTE
If the depth sensor detects an invalid depth the
following displays.
Reposition the rod at the correct depth. If the error
continues, use the gauge in Manual Depth mode (see
or Manual Depth on page 3–
12) until it can be serviced by a Troxler authorized
service center. In the Manual Depth mode, you will be
prompted to enter the depth.
5
5
.
.
After the measurement completes, raise the handle to the
SAFE
position and follow the instructions on the display.
Press
〈
YES
〉
if conditions have not changed since
performing the standard count or background count.
Follow the prompts on the display to complete the
measurement.
Depth: x in
PR:
xxx.x pcf
Time: xxx s
Invalid Depth
Press <ENTER>
BGD= xxxx
Is this background
Count current
Press <YES> or <NO>