4–4
Figure 6. Marking the Test Area
7
7
.
.
Carefully pick up the scraper plate. Be careful not to disturb
the soil around the hole.
8
8
.
.
Position the Gauge on the prepared area inside the
markings.
9
9
.
.
To ensure correct positioning of the Gauge, lower the
source rod into the prepared hole.
Use care when
inserting the source rod; do not to disturb the soil
around the hole.
1
1
0
0
.
.
Raise the source rod back to the SAFE position.
1
1
1
1
.
.
You are now ready to perform your measurement
NOTE:
Perform the standard count at least once a day.
The best practice is to perform the standard count at
the jobsite on the first test site of the day.