SpeedMarker 300 /
ProMarker 300
Ausgabe 1.0
Technische Änderungen vorbehalten.
TROTEC Produktions- u. Vertriebs GmbH
Linzer Straße 156, A
– 4600 Wels
Seite
30
von 42
Connector X83 is connected to the cable from the laser module. This cable leads from the laser module via the
black tube to X82 on the marking head.
The monitor, mouse and keyboard must also be connected to the PC. (Monitor, mouse and keyboard are not nor-
mally included in the scope of supply.)
Note: the PC COM4 interface is not connected prior to delivery!
8.2.2
Power Supply
IEC connectors are located on the reverse side of the laser module and PC for the connection of the supplied IEC
power cords.
Before putting the system into operation, it is essential to check whether the laser module is configured to the
available supply voltage and frequency.
The configuration of the laser module is given on the type plate or warning sign above the IEC connector.
The laser module is fitted with different main fuses depending on the configured supply voltage:
115V AC
-
1 X 6.3
A “T” speed/time-delay
230V AC
-
2 x 4
A “T” speed/time-delay
The main fuses are located behind the cover, immediately adjacent to the IEC connector.
The same main fuse is used for all supply voltages on the PC.