Possible Error Messages
Below is a list of possible errors which may be detected by the system. These will appear in the software as mes-
sages on the display.
The Reset signal (X11) or the reset button on the laser module are used to acknowledge an error. In
order for the system to be reset, the error or the corresponding input signal must be acknowledged.
System errors which cannot be reset or which indicate a hardware error should only be re-
solved by Trotec Produktions und Vertriebs Ges.m.b.H. trained service personnel.
Error message
Cause
Card off line
Software has lost connection to the TLC2 controller
Scanner not connected
No connection to the galvo
Scanner X error
The galvo X-axis has identified an error
Scanner Y error
The galvo Y-axis has identified an error
Signal cable not connected
No connection to the marking head
External abort
External abort signal identified on X11
External stop
External stop signal identified on X11
Voltage error (15V)
+/- 15V power supply not functioning correctly
Voltage error (24V)
24V power supply not functioning correctly
Laser power supply error
Faulty laser source power supply
Shutter error
Shutter has not reached intended position
Cover connector opened dur-
ing marking
ICL1 and ICL2 were opened during the marking process
External sum alarm
External error signal identified on X11
System locked by key switch
Key switch on laser module locked
Laser temperature
Laser source overheated
Laser power
24 V power supply outside the permissible tolerance zone
Laser not ready for emission
e.g. key switch not activated
Laser back reflection
Back reflection of the laser beam
Laser system error
Laser power supply voltage is too high or too low
Emergency stop button
Emergency stop button activated
System Failurer